PSEN op4H-SL Series
Appendix
Check list
The checklist below is intended as an aid in for the following work on a safety light grid of
PSEN op4H-SL Series:
commissioning,
}
recommissioning, and
}
running the specified regular check.
}
Note that the check list is not intended to replace the plant-specific safety analysis required
for commissioning/recommissioning, nor the resulting inspections and actions.
We recommend that you keep the completed check list and store it with the machine docu-
mentation for reference.
No. Action
1
2
3
4
Operating Manual PSEN op4H-SL Series
1004305-EN-01
INFORMATION
Commissioning, recommissioning and regular inspection may only be car-
ried out by qualified personnel.
Check the category/standards
Does the category of the safety light grid
match the category required for the plant/
machine?
Have the standards applicable for the plant/
machine been considered?
Check the safety light grid ambient con-
ditions
Have the environmental conditions been
met (see
Ambient conditions [
Have the technical details been met for all
the safety light grid components?
Check access to the hazardous area
Are all access points to the danger zone
safeguarded by either safety light grids or
mechanical safeguards?
Check the minimum distance to hazard-
ous area
Has the minimum distance been calculated
in accordance with the applicable stand-
ards?
Has the calculated minimum distance been
maintained at all points?
OK
14])?
NOT OK Notes
51