Safety Characteristic Data - Pilz PSEN op4H-SL Series Operating Manual

Safety light grid for hand protection
Table of Contents

Advertisement

PSEN op4H-SL Series
Environmental data
Shock stress
In accordance with the standard EN 60068-2-29
Number of shocks
Acceleration
Duration
Protection type
In accordance with the standard EN 60529
Housing
Mechanical data
Cable length L1
Min. bending radius (fixed perman-
ently) K1
Min. bending radius (fixed perman-
ently) cascading cable
Cable insulation material K1
Connection type
Receiver
Transmitter
Max. cable length
Material
Top
End caps
Front screen
Max. torque setting
Fixing screw
Cover for cascading adapter
Dimensions
Height
Width
Depth
Weight

Safety characteristic data

Operating Manual PSEN op4H-SL Series
1004305-EN-01
631126
1000
10g
16 ms
IP65
631126
0,2 m
1 x Ø
1 x Ø
PVC
M12, 5-pin male connector
M12, 5-pin male connector
20 m
Aluminium
Zamak
PMMA
1,2 Nm
0,2 Nm
1.050 mm
15,4 mm
32,6 mm
1.250 g
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
631127
EN 60068-2-29
1000
10g
16 ms
EN 60529
IP65
631127
0,2 m
1 x Ø
1 x Ø
PVC
M12, 5-pin male connector
M12, 5-pin male connector
20 m
Aluminium
Zamak
PMMA
1,2 Nm
0,2 Nm
1.200 mm
15,4 mm
32,6 mm
1.400 g
48

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents