Operating Manual Psen Op4H-Sl Series - Pilz PSEN op4H-SL Series Operating Manual

Safety light grid for hand protection
Table of Contents

Advertisement

PSEN op4H-SL Series
Check the safety function of the safety light grid
Procedure
In each of the stated tests, the OSSDs must switch to the OFF state and the OSSD status
LED on the receiver must light up red: 
1. Move the test rod slowly through the protected field (see diagram):
2. Place the test rod at rest in a position in the protected field that is considered critical for
the safety assessment results
Legend
[1] Test rod
Check ambient conditions and installation
Correct alignment and attachment
}
Check the seating of the mounting screws by applying pressure to the edges of the
safety light grid. The OSSD LED
Safety distance
}
The safety distance must comply with the requirements in Maintaining the safety dis-
tance.
Circumventing the protected field
}
The danger zone must be secured so that it is impossible to access by circumventing
the protected field.

Operating Manual PSEN op4H-SL Series

1004305-EN-01
In the vicinity of the transmitter
In the vicinity of the receiver
In the centre of the protected field
.
OSSD
[1]
on the receiver must not light up red.
OSSD
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents