BIOS Diagnostics 194DI Instruction Manual

Dual ear/forehead thermometer

Advertisement

dUAL
EAR/FOREHEAd
THERMOMETER
INsTRUCTION
MANUAL
BIOS
Diagnostics

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 194DI and is the answer not in the manual?

Questions and answers

Summary of Contents for BIOS Diagnostics 194DI

  • Page 1 dUAL BIOS EAR/FOREHEAd Diagnostics ™ THERMOMETER INsTRUCTION MANUAL...
  • Page 2: Table Of Contents

    194DI Dual Ear/Forehead Thermometer Instruction Manual Table of Contents Important Safety Instructions Product Diagram How this Thermometer Measures Temperature Directions for Use - Ear Mode Directions for Use - Forehead Mode Fever Alarm Changing from Celsius to Fahrenheit Memory Storage...
  • Page 3 Dual Ear/Forehead Thermometer Thank you for purchasing the BIOS Diagnostics™ Dual Ear/Forehead Thermometer. The BIOS Diagnostics™ Dual Ear/Forehead Thermometer is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, this thermometer can provide safe, accurate and reliable readings with each measurement on people over 2 years of age.
  • Page 4: Important Safety Instructions

    Multiple Reading Recall Users will be able to recall the last 12 readings when entering the recall mode, enabling efficient tracking of temperature variations. Fever Alarm 10 short beeps and a red LCD backlight alerts the patient that he/she may have a temperature above 37.4°C/99.3°F.
  • Page 5 • This thermometer consists of high quality precision parts. Do not drop this instrument. Protect it from severe impact and shock. • Keep the thermometer away from direct exposure to the sun and keep it in a dust-free dry area. •...
  • Page 6: Product Diagram

    2. PRODUCT DIAGRAM Measuring Sensor START Button LCD Display ON/OFF Button 3. HOW THIS THERMOMETER MEASURES TEMPERATURE Forehead Measurement The thermometer measures infrared energy radiated from the skin above the eyebrow area and the surrounding tissue. This energy is collected through the lens and converted to a temperature value.
  • Page 7: Directions For Use - Ear Mode

    Measurements taken from the surrounding tissue of the ear canal generate lower readings and may result in misdiagnosis of fever. 4. DIRECTIONS FOR USE - EAR MODE IMPORTANT: If using the thermometer for the first time, remove the plastic strip located in the battery compartment. 1.
  • Page 8: Directions For Use - Forehead Mode

    • Always clean the probe accordingly before and after each use (See Care and Cleaning). • It is recommended that you measure the temperature 3 times in the same ear. If the 3 measurements are different, select the highest one. (Allow 30 seconds between each measurement).
  • Page 9 5. Press the START button once and release it. Start to move the instrument steadily from 1 cm above the center of the eyebrow to the temple area. A long beep sound will emit after 3 seconds to acknowledge the completion of measurement.
  • Page 10: Fever Alarm

    6. FEVER ALARM If the thermometer detects a body temperature greater than 37.4°C/99.3°F, it will make 10 short beeping sounds and the LCD will light up RED, indicating a potential fever. 7. CHANGING BETWEEN CELSIUS AND FAHRENHEIT This thermometer can display temperature measurements in either Celsius or Fahrenheit.
  • Page 11: Measuring Surface Temperatures

    • Reading 12 - reading in succession: Press and release the START button consecutively to recall the last 12 readings in succession. Pressing and releasing the START button after the last 12 readings have been recalled will resume the above sequence from reading 1. 9.
  • Page 12: Battery Replacement

    Remove the battery cover by sliding it in the direction shown. Remove the battery and replace with a new one. 12. TECHNICAL SPECIFICATIONS Type : Dual Ear/Forehead Mode Thermometer 194DI Measurement range: Ear Mode: 0°C to 100.0°C/32°F to 212.0°F Forehead Mode: 34°C to 42.2°C/93.2°F to 108.0°F Resolution: 0.1°C/°F...
  • Page 13 Acoustic: • The unit is turned ON and ready for the measurement: 1 short beep • Complete the measurement: 1 long beep (1 second) if the reading is less than 37.5°C/99.5°F, 10 short beeps sound, if the reading is equal to or greater than 37.5°C/99.5°F •...
  • Page 14: Troubleshooting

    13. TROUBLESHOOTING Error Message Problem Solution The system is not Unload the battery, wait functioning properly. for 1 minute and repower Temperature taken is higher than 100.0°C/212.0°F in the ear mode or 42.2°C/108.0°F in the forehead mode. Temperature taken is lower than 0°C/32.0°F in the ear mode or 34.0°C/93.2°F in the forehead mode.
  • Page 15: Lifetime Warranty

    Please check if the steady Battery should be replaced battery icon is the only immediately. symbol shown on the display. Please check if the battery Reinstall the battery. has been loaded correctly. Check the polarity of the battery. 14. LIFETIME WARRANTY This product is warranted to be free from defects in material or workmanship for the life of the original owner.

Table of Contents