  • Page 1 BIOS COMPACT EAR Diagnostics ™ ThERMOMETER InsTRuCTIOn MAnuAl...
  • Page 3: Table Of Contents

    BIOS 120DC Compact Ear Thermometer Instruction Manual Diagnostics Table of Contents Important Safety Instructions Product Diagram Directions for Use - Inserting the Battery Ear Mode Fever Alarm Memory Storage Measuring Temperature - Scan Mode Measuring the Room Temperature Changing from Celsius to Fahrenheit...
  • Page 4 120DC Diagnostics Thank you for purchasing the BIOS Diagnostics™ Compact Ear Thermometer. The BIOS Diagnostics™ Compact Ear Thermometer is a high quality product incorporating the latest technology, and tested in accordance with international standards. With its unique technology, this thermometer can provide safe, accurate and reliable readings with each measurement, on people over 2 years of age.
  • Page 5: Important Safety Instructions

    Do not drop this instrument. Protect it from severe impact and shock. WARNING • Use of this BIOS Diagnostics™ Compact Ear Thermometer is not intended as a substitute for consultation with your physician. • Keep the protective storage cover out of the reach of children. Small pieces may be ingested and present a choking hazard.
  • Page 6 concerns, and therefore, parents should not rely solely on temperature readings to evaluate the status of your child’s health. If you have any concerns, consult with your doctor.
  • Page 7: Product Diagram

    2. PRODUCT DIAGRAM...
  • Page 8: Directions For Use - Inserting The Battery

    3. DIRECTIONS FOR USE - INSERTING THE BATTERY 1. Slide and remove the battery cover located on the back of the thermometer. 2. Insert the battery (included) under the metal hook on the top and press the battery down until you hear a click. Insert the battery with the “+” side facing up.
  • Page 9 3. Press and hold the SCAN button until you hear a beeping sound. Remove the probe from ear and the temperature measurement is displayed on the screen. The thermometer will beep two more times for final confirmation of the measurement. It is now ready to take another measurement. 4.
  • Page 10: Fever Alarm

    How to Straighten the Ear Canal? • For ages 2 years to adult: Gently pull the outer ear “up and back” to straighten the canal. Fully insert the thermometer gently into the ear. • It is recommended that you measure the temperature 3 times in the same ear.
  • Page 11: Memory Storage

    6. MEMORY STORAGE When in “ear mode” press ON/MEM to view the stored temperatures. The stored temperatures are indicated with the . Keep pressing ON/MEM to scroll through each stored temperature. The thermometer stores 25 sets of temperatures for ear measurements. 7.
  • Page 12: Measuring The Room Temperature

    8. MEASURING THE ROOM TEMPERATURE The room temperature is continuously displayed when the unit has been left idle for more than 1 minute. It is shown on the display screen with the icon. The temperature will be updated every 15 minutes. For a more accurate room temperature reading, the thermometer should be placed on a table and away from direct sunlight or air conditioner flow.
  • Page 13: Care And Cleaning

    10. CARE AND CLEANING • After each use, use an alcohol swab or cotton swab moistened with alcohol (70% Isopropyl) to clean and disinfect the probes and thermometer casing. • Keep the unit dry and away from any liquids and direct sunlight. •...
  • Page 14: Specifications

    12. SPECIFICATIONS Temperature Measurement Range: • Ear Mode: 34°C to 42.2°C (93.2°F to 108°F) • Scan Mode: -22°C to 80°C (-7.6°F to 176°F) Operating Temperature Range: • 10°C to 40°C (50°F to 104°F) Storage Temperature Range: • -20°C to 50 °C (-4°F to 122°F), RH ≤ 85 % •...
  • Page 15: Troubleshooting

    13. TROUBLESHOOTING Error Message Problem Solution Error 5-9, the system is not Unload the battery, wait functioning properly. for 1 minute and repower Measurement before Wait until all the icons device stabilization. stop flashing. The device showing a Allow the thermometer rapid ambient temperature to rest in a room for at change.
  • Page 16 (1) In Ear: Temperature taken is higher than 42.2°C (108°F). (2) In Scan Mode: Temperature taken Please select the is higher than 80°C appropriate mode for (176°F). temperature type required. (1) In Ear: Temperature taken is lower than 34°C (93.2°F). (2) In Scan Mode: Temperature taken is lower than - 22°C...
  • Page 17: Two Year Warranty

    14. TWO YEAR WARRANTY If this product proves to be defective in material or workmanship within two years of purchase, it will be repaired or replaced without charge upon receipt of the unit prepaid with $5.00 to cover handling, packaging and return postage to the address below.