Siemens FDA241 Series Manual

Siemens FDA241 Series Manual

Hide thumbs Also See for FDA241 Series:

Advertisement

Quick Links

FDA241, FDA221
Siemens ASD
l
Patented Technology
l
Compatible with the Siemens FDnet/C-NET loops (requires FDCC221S option)
Advanced dual Wavelength optical detection (Blue & Infra-red)
l
Configurable as a Standalone via a USB port or via the Panel when on a
l
network loop using the optional FDCC221S
Out-of-the-box installation and commissioning
l
l
Early detection of a wide range of airborne particle sizes
l
Asyst software tool for sample pipe designs support
l
Programmable alarm thresholds
l
The unique chamber design ensures clean detection chamber optics
l
Instant recognition front panel display
Normalize Smoke
l
l
Normalize Air flow
Easy field service accessibility
l
Multiple event logging
l
l
Offline/online configuration capability
FDA241 Up to 800 m
l
l
FDA221 Up to 500 m
l
4...20 mA output
l
Purge functionality (FDA241)
2
coverage
2
coverage
Building Technologies
TM
Sinteso
Cerberus™ PRO
CPS Fire Safety

Advertisement

loading

Summary of Contents for Siemens FDA241 Series

  • Page 1 Cerberus™ PRO Siemens ASD Patented Technology Compatible with the Siemens FDnet/C-NET loops (requires FDCC221S option) Advanced dual Wavelength optical detection (Blue & Infra-red) Configurable as a Standalone via a USB port or via the Panel when on a network loop using the optional FDCC221S...
  • Page 2 Siemens ASD FDA Series The FDA241/221 series of detectors are a very early warning dual wavelength (blue & infra-red) smoke detectors designed to protect small to medium, business- critical environments up to 800 m with the FDA241 or 500 m with the FDA221).
  • Page 3 Legend to Indicators Opening the detector There are 2 modes for accessing the detector service area. Partial access Remove the 2 screws on the top of the detector. Slide the front cover upward until it reaches the self locking tabs. Full access Remove the 2 screws on the top of the detector.
  • Page 4 The detector will cycle through a full LED display to check the operation of all LEDS If connecting the Siemens ASD directly to a Siemens FDnet, C-NET loop, the FDCC221S communication card must be ordered as a separate item. (S24218-A201-A2)
  • Page 5 Up to 800 m² Up to 500 m² Area coverage and standards System compatibility compatible with all Siemens FC20/FC720 (FS20/FS720 system) Alarm Relay outputs selectable Latching/Non Latching Qty 4 Qty 3 rated 2.0A @ DC 30 V (max). NO/NC Contacts...
  • Page 6 Technical manual for Aspirating Smoke Detectors FDA241, FDA221, Document A6V10334410 Technical manual for Power supply kit FP120-Z1, Document A6V10393194 Siemens Switzerland Ltd © Siemens Switzerland Ltd, 2014 Building Technologies Division Data and design subject to change without notice. International Headquarters Supply subject to availability.