Download Print this page

Whirlpool ADO15 Use And Care Manual page 13

Whirlpool dehumidifiers use and care guide

Advertisement

5. For models AD025, AD030, ADO40 and
AD050:
Remove the rear grille by pulling out
at bottom and dropping grille down.
6. Lift cabinet off unit base.
7. Brush coils clean, if necessary, with warm
water and a mild detergent. Rinse and dry
thoroughly.
Be sure the power supply
cord
is disconnected
from the electrical
outlet
NOTE: The compressor
is sealed and needs
no oiling. The fan motor is prelubricated
and
does not require further oiling under normal
operating conditions. However, if the
dehumidifier
is operated under severe
environmental
conditions (dust, dirt, high
temperatures)
the fan motor should be oiled
annually. Follow the instructions in step 8.
8. Oil the fan motor through the tubes provided.
An easy-to-use
capsule of especially
recommended
oil (Part No.
10943)
is
available from your nearest authorized
Whirlpoolse service company, or use SAE
#20 non-detergent
oil.
Coile
Fan motor
9. Wash all plastic parts with a soft cloth, warm
water and a mild detergent.
Rinse and dry
them with a soft cloth.
10. Replace cabinet and grille(s).
11. Reconnect dehumidifier to power supply.