WELCOME Thank you for purchasing an ARTHUR HOLM product. Our product range has been designed for a seamless integration and for a maximum reliability. Please, read this installation and operating instructions carefully and keep them in a safe place for future reference.
Page 5
ABOUT US The Company Arthur Holm has its origins in the Danish furniture designer Jorgen Alex Jensen, who was active during the sixties and the seventies. His design inspiration and his concept of ergonomics have been continued by his family, who is the design force behind Arthur Holm product range. The...
EC REGULATIONS AND SECURITY ATTENTION: Do not disassemble or modify the device in any way. This symbol warns of the presence of dangerous un-insulated voltages inside some of the components, of sufficient magnitude to expose people to risk of electronic shock. This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit.
Page 7
SAFETY INSTRUCTIONS Wiring connected to hazardous voltage requires installation by qualified personnel or the use of ready-made flexible cables. For your security, your equipment must be connected to an electrical outlet with grounding connection protection. Since the plug is used to disconnect the device, the operating electrical outlet must be in an easily accessible place.
The DynamicVision is designed to be adapted to the room décor. Its mounting system allows for the mounting of fabric of your choice onsite. The DynamicVision can also be veneered with a maximum veneer load of 2.5 kg / 5.5 lbs. The camera enclosure is controllable through RS-422 (AHnet), Infrared or AHlink.
Page 9
SYSTEM DESCRIPTION Features • Motorised wall mount for videoconference cameras. • Compatible with most popular videoconference cameras. • Cover for veneering. • RS-422 and Infrared controllable. • Easy to install. Models AHDV01 Motorised camera wall mount enclosure for videoconference cameras. Upward moving cover.
INSTALLATION Support wall mounting DynamicVision is designed to be mount on any wall. Installation is extremely simple: • Attach the enclosure into the hole previously made. Use suitable hardware in the 4 holes. • Once the system connections are done, match the front cover to the...
Page 11
• Push the control button on the remote control, to lift the cover. The DynamicVision's cover will then open and the tray will move horizontally outward. • Place now the platform with the camera already fixed and connected (recommended) in the DynamicVision's movable tray.
INPUT CONNECTORS AHnet: RJ45 CAT5 connector for addressable RS422 control. There is a loop through connector to use as signal RS422 output. Up to 30 devices can be connected on the same RS422 bus. Termination: Activate (ON) the termination ONLY, on the last device of the RS422 bus.
CONTROLS Push the top arrow to lift the front cover. Please be sure that there is nothing that may obstruct the path of the device's vertical movement. While the cover moves upwards, the tray that supports the video conference camera moves forward. Please be sure that there are also no obstructions on its path.
Page 14
AHLINK AHlink is used to control and set-up the unit. Download AHlink from the App Store (IOS system) or from Google Play (Android system). The App is free. Execute the AHlink on your mobile phone. On the AHlink App options, it is recommended to not select Auto Connect and select Portrait on Orientation.
Page 15
AHLINK If the device does not appear on the window, the AHlink signal is not active. To activate, press right narrow on remote IR controller. The AHlink name always begins with AH characters and the fourth last MAC AHlink address. Select the device to control and set up the unit.
Page 16
AHLINK The first line shows the model name of the device. SERIAL Serial number of the unit Firmware version Controls the Up and Down screen movements COMMAND: Information of the last AHnetcommand received from RS 422 port SENSORS: Indicates sensor status. S1: indicates the inside tray position S2: indicates the outside tray position S3: indicates the open cover position...
AHNET PROTOCOL Communications protocol COMMUNICATION RS422 CONNECTION RJ45 WIRING CAT-5 Speed and configuration BAUD RATE 38400 DATA BITS PARITY NONE STOP BITS Wiring Diagram 1. Data TX + 2. Data TX – 3. Data RX + 4. NC 5. NC 6 .Data RX –...
Page 18
AHNET PROTOCOL AHnet protocol Using 5 bytes communication: BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE BYTE 3 VALUE 1 BYTE 4 VALUE 2 Commands COMMAND DESCRIPTION RESPONSE FA XX 01 01 00 GO UP FB XX 01 01 00 FA XX 01 00 00 GO DOWN FB XX 01 00 00...
INFORMATION ON DISPOSAL FOR USERS OF WASTE ELECTRICAL & ELECTRONIC EQUIPMENT This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to the designated collection points, where they will be accepted on a free of charge basis.
WARRANTY TERMS AND CONDITIONS Albiral Display Solutions warrants this product against manufacturing defects and workmanship for a period of two (2) years from the date of purchase, subject to the conditions below. Electrical, electronic boards, accessories and power supply are warranted against manufacturing defects and workmanship for a period of two (2) years from the date of purchase Labour costs: Albiral Display Solutions covers the labour costs to...