Innovator Plus Control Box Component Manual This manual is applicable to the following models: INV3-CB-100-10 INV3-CB-100-10T Rev. May 2019...
Page 2
Innovator Plus Control Box Manual ORPORATE EADQUARTERS 2030 Falling Waters Rd, Suite 350, Knoxville, TN 37922 · USA · Tel: (865) 686-5670 ISTRIBUTION AND URCHASING 642 Barbrow Ln, Knoxville, TN 37932 · USA · Tel: (865) 684-4416 ECHNOLOGY ENTER AND ANUFACTURING 1862 Ives Ave, Kent, WA 98032 ·...
Innovator Plus Control Box Manual Table of Contents Section Page Table of Contents Safety & Warning Information Introduction Installing Control Box Operating Controls Setting Up System Optional Controls Page | 3...
MVP assumes no responsibility for loss, damage, expense or claims for bodily injury or property damage, direct or consequential, arising from the use of such chemical components.
Page 5
Innovator Plus Control Box Manual Safety Precautions Avoid skin contact and inhalation of all chemicals. Review Material Safety Data Sheet (MSDS) to promote the safe handling of chemicals in use. Restrict the use of all chemicals to designated areas with good ventilation.
Page 6
An improperly loaded drum may lead to an imbalance, causing a unit to tip over Personal Protective Equipment (PPE) MVP recommends the use of personal safety equipment with all products in our catalog. Wear safety goggles, hearing protection, a respirator, and chemical resistant gloves.
Page 7
Innovator Plus Control Box Manual Symbol Definitions Indicates the risk of Indicates the risk of contact with chemicals contact with voltage / that are hazardous, which amperage that may lead may lead to injury or to serious injury or death death.
Page 8
Innovator Plus Control Box Manual Polymer Matrix Materials: Advanced Composites Potential health hazards associated with the use of advanced composites can be controlled through the implementation of an effective industrial hygiene and safety program. https://www.osha.gov/dts/osta/otm/otm_iii/otm_iii_1.html#t iii:1_1 Resins Composite Component Organ System Target...
Page 9
Innovator Plus Control Box Manual Catalyst - Methyl Ethyl Ketone Peroxide (MEKP) MEKP is among the more hazardous materials found in commercial channels. The safe handling of the “unstable (reactive)” chemicals presents a definite challenge to the plastics industry. The...
Page 10
Innovator Plus Control Box Manual Never add MEKP to anything that is hot, since explosive decomposition may result. Avoid contact with skin, eyes, and clothing. Protective equipment should be worn at all times. During clean-up of spilled MEKP, personal safety equipment, gloves, and eye protection must be worn.
Page 11
Innovator Plus Control Box Manual The reaction is unpredictable. Prior use of an HHC solvent without incident (corrosion or explosion) does NOT mean that such use is safe. These solvents can be dangerous alone (as a clean-up or flushing agent) or when used as a component or a coating material. There is no known inhibitor that is effective under all circumstances.
Page 12
Innovator Plus Control Box Manual Catalyst Diluents Magnum Venus Products spray-up and gel-coat systems currently produced are designed so that catalyst diluents are not required. Magnum Venus Products therefore recommends that diluents not be used to avoid possible contamination which could lead to an explosion due to the handling and mixing of MEKP and diluents.
Page 13
Innovator Plus Control Box Manual Toxicity of Chemicals Magnum Venus Products recommends that you consult OSHA Sections 1910.94, 1910.106, 1910.107 and NFPA No.33, Chapter 14, and NFPA No.91. Contact your chemical supplier(s) and determine the toxicity of the various chemicals used as well as the best methods to prevent injury, irritation and danger to personnel.
Page 14
Innovator Plus Control Box Manual Precautions include: 1. Know precisely what chemicals you are using and obtain information from your chemical supplier on what to do in the event the chemical gets onto your skin or into the eyes, or if swallowed.
MVP dispensing system, whether it is the innovative Patriot, the rugged Universal Proportioner, or anything in between. The controls can process large shot of hundreds of pounds or as small as 5 ccs. The Innovator Plus can be used for various applications, including: ...
Page 16
Innovator Plus Control Box Manual Models and Options The Innovator Plus controls package comes in 4 versions. Models will accept almost any MVP pump configuration available. For larger or custom configurations, please contact your local MVP representative. Permanent Mount Platform Systems ...
Page 17
HDPE 5-gallon gravity of 2-gallon suction feed hardener tank Pneumatic closed loop injection pressure control Using the inline mold pressure guard (MPG) from MVP, injection pressure can be reduced or stopped by sensing backpressure from the injection line ...
Page 18
Electronic closed-loop injection pressure control Using the inline MPG from MVP, with or without a pressure transducer, the injection pressure can be reduced/stopped by sensing backpressure from the injection line. This option is for finer control of the inlet pressure and can be set...
Installing Control Box The Innovator Plus comes standard with a 10 foot power cord. The control unit can be run with 110 VAC or 220 VAC (5A draw). If the EHC-X option is installed, the unit must be powered at 220 VAC (30A draw).
Page 20
Innovator Plus Control Box Manual Status Indicator Pump Pressure Gauge & Regulator Alarm Light Touchscreen HMI MPG Gauge & Power & Mode Function Buttons Regulator Switches Figure 4. Front View Optional Inputs Figure 4. Bottom View Page | 20...
Page 21
Innovator Plus Control Box Manual SECURELink Enable/Disable Switch USB Port Figure 6. Right Side Pneumatic Controls Figure 6. Control Box Left Side View (Cover Removed) Control Panel Lights Status Indicator Machine Status Indicator Alarm Status Indicator Lights Light Indicates Orange Status Indicator...
Page 22
Depending on machine configuration not all options on all screens may be available. The Innovator Plus control system will vary slightly depending on the model/options ordered. This manual only covers the controllers and their operation. For pumping system details, consult the manual for the specific component or system.
Page 23
Innovator Plus Control Box Manual Figure 7. HMI Screen Flow Page | 23...
Page 24
Innovator Plus Control Box Manual Startup Screen Status Indicators Controls The Startup screen displays when the system is initialized. It displays the current date and time, followed by machine status indicators and then controls to navigate the system. Startup Screen Status Indicators...
Page 25
Innovator Plus Control Box Manual Security Login/Machine Setup Screen On the Security Login/Machine Setup screen, you can enter passwords to access certain areas of the HMI. The default passwords are as follows: Level 1 Level 2 Level 3 The first time Level 3 is accessed, it is recommended that the password be reset.
Page 26
Innovator Plus Control Box Manual Injection Monitoring and Controls Screen Injection Monitoring Screen Controls Button Function START Starts either manual dispense or automatic injection mode PAUSE Pauses automatic injection mode STOP Stops all function of the machine PURGE Engages solvent purge system SRPUE CONTROL –...
Page 27
Innovator Plus Control Box Manual Injection Monitoring Screen Settings Electronic Mold Pressure Guard (EMPG) Controls Setting EMPG HIGH Pressure setting at which auto injection will pause EMPG LOW Vacuum setting at which auto injection will pause Note Once the EMPG has reached the high setting the unit must be off for a minimum of 10 seconds for the injection to resume.
Page 28
Innovator Plus Control Box Manual Injection Monitoring Screen Alarms/Status Indicators This field Displays FLOW/MIN Flow per minute of fluid INJECTION TIME Accumulated injection time CURRENT PUMP PRESSURE SETTING Pump pressure setting CURRENT CATALYST SETTING Current catalyst leve HEATER #1 Running temperature of heater #1...
Page 29
Innovator Plus Control Box Manual Heat Control Screen Alarms/Status Indicators This display Indicates TEMPERATURE Current temperature of the heater thermocouple THERMOCOUPLE FAILURE Resin heater thermocouple is not operating correctly HEATER LIMITS Sets the upper and lower limits of the heater. If the heater overruns the upper limit it will shut down.
Page 30
Innovator Plus Control Box Manual Recipe Load/Delete Screen Status Indicators This display Indicates RECIPE LOADED When recipe is loaded and ready to start injection LOADING RECIPE Recipe currently loading INJECTING Active when injecting Note DO NOT load or delete recipe while injecting!
Page 31
Innovator Plus Control Box Manual parameters are not entered or bypassed, a warning will display and not allow the recipe to be saved. Any time a red box blinks around a parameter, it is out of range and has not been entered correctly.
Innovator Plus Control Box Manual Recipe Create Screen Controls Button Function RECIPE NUMBER Recipe number to overwrite/delete SAVE RECIPE Saves selected recipe to system Note When overwriting an existing recipe you must confirm before the save is finalized. RESET Clears fields to start over...
Page 33
Innovator Plus Control Box Manual To program a tag, follow these steps: 1. Place a tag in front of the read/write head. 2. Enter a recipe number that the tag will represent. 3. Press the WRITE # TO TAG button.
Page 34
Innovator Plus Control Box Manual The barcode must be organized in the following order: RECIPE, SERIAL, MODEL. You may omit the serial number, model number, or both, but you must maintain the order structure. The employee number and its indicator are optional, but if you include it note that it does not get reset every scan.
Page 35
Innovator Plus Control Box Manual WARNING These settings should only be adjusted by qualified personnel. Failure to adjust/setup the PSD properly can result in equipment and/or part damage. Progressive Slave Drive Setup Screen Controls Button Function ENABLE/DISABLE Enables or disables the PSD...
Page 36
Innovator Plus Control Box Manual Recirculation Recirculation Setup Field/Button Function MODE – TIMED Uses set parameters to run recirculation at certain intervals MODE – AUTO Runs recirculation immediately after dispense gun is disengaged MODE – MANUAL In this mode the operator must turn the...
Page 37
Innovator Plus Control Box Manual Calibration Setup Calibration Setup Field/Button Function START Starts calibration mode CALIBRATION SCALE FACTOR Adjustment to match output with counter/flow meters STOP Stop calibration mode CALIBRATION SAMPLE SIZE Entry for sample size dispensed UNIT SELECTOR Sets machine labels to units being...
Page 38
Innovator Plus Control Box Manual Hardener Alarm Setup Hardener Alarm Setup Field/Button Function ENABLED/DISABLED Turns the catalyst alarm on or off BYPASS TIME (SEC) Delay time in seconds before catalyst will respond RECIRC ALARM Disable/enable catalyst alarm during ENABLED/DISABLED recirculation...
Page 39
Innovator Plus Control Box Manual Heat Control Setup Screen Heat Alarm Setup Screen Controls Button Function HEAT ALARMS ENABLED/DISABLED Enable/disable heat alarm access HEATER #X ON/OFF Enable/disable individual alarms LOW SETPOINT Low point for alarm to trigger HIGH SETPOINT High point for alarm to trigger...
Page 40
Innovator Plus Control Box Manual Maintenance Setup Screen On the maintenance setup screen, the controls and status indicators are common to each category displayed. Maintenance Setup Screen Controls Button Function RESET Enter the run time for the component at which a...
Page 41
Innovator Plus Control Box Manual Input / Output Status Screen Input/Output Direction Setup Screen Status Indicators Field Displays DIRECT INPUTS Each display corresponds with a sensor or switch. The indicator will turn green when the PLC is activated. DIRECT OUTPUTS Each display corresponds with a valve or light.
Page 42
Innovator Plus Control Box Manual The analog input screens are used to tune the transducers placed on the system. Due to the different transducers available, there are settings that need to be tuned specifically for the type of transducer installed.
Page 43
Innovator Plus Control Box Manual Analog Inputs 2/3 (Vacuum/EMPG Transducers) The analog input screens are used to tune the transducers placed on the system. Due to the different transducers available, there are settings that need to be tuned specifically for the type of transducer installed.
Page 44
Innovator Plus Control Box Manual EMPG Transducer Analog Input #3 Setup Status Indicators Field Displays BIT SPAN Range of sensor in PLC TRUE ZERO Reading of sensor at atmospheric pressure SCALED ZERO Reading of sensor installed in fluid housing OFFSET...
Current output from PLC RAW OUTPUT Raw output from PLC Optional Controls Depending on which options were ordered, the Innovator Plus control package may include optional controls. Pneumatic Controls Manual Pump Speed Control If the EPPC regulator option is not ordered, the pumping system pressure/speed must be controlled manually via the regulator on the front panel.
Page 46
Fluid Controls Catalyst Back Pressure Valve The Innovator Plus comes standard with a recirculation package. In order to preserve the efficient mix meter characteristic of the MVP pumping system, a balance must be achieved between dispense mode and recirculation mode for fluid pressures, mainly the catalyst injection pressure.
Page 47
Innovator Plus Control Box Manual the dispense pressure to ensure that in dispense mode the catalyst pressure does not have to build to be injected into the resin stream and mixed properly. If the pressure is set too high, a hot spot will appear where too much catalyst has been introduced at the beginning of the dispense cycle.
Page 48
Innovator Plus Control Box Manual Progressive Slave Drive Page | 48...
Page 49
Innovator Plus Control Box Manual ORPORATE EADQUARTERS 2030 Falling Waters Rd, Suite 350, Knoxville, TN 37922 · USA · Tel: (865) 686-5670 ISTRIBUTION AND URCHASING 642 Barbrow Ln, Knoxville, TN 37932 · USA · Tel: (865) 684-4416 ECHNOLOGY ENTER AND ANUFACTURING 1862 Ives Ave, Kent, WA 98032 ·...