Download Print this page

Whirlpool wgd9200s Dimensions And Installation Information page 3

Gas dryer

Advertisement

®
PRODUCT MODEL NUMBERS
WGD9200S
WGD9400S
WGD9300V
WGD9400V
RECOMMENDED INSTALLATION SPACING FOR RECESSED OR CLOSET INSTALLATION, WITH STACKED WASHER AND DRYER
Dimensions shown are for recommended spacing.
2
48 in.
*
2
(310 cm
)
3"* (76 mm)
3"* (76 mm)
2
24 in.
*
2
(155 cm
)
CUSTOM UNDERCOUNTER INSTALLATION – DRYER ONLY
Dimensions shown are for minimum spacing.
A
B
C *
* Required spacing
EXHAUST VENTING
A and B: Recommended hood styles.
C: Acceptable hood style.
B
A
4"
(102 mm)
4"
A. Louvered hood style
(102 mm)
B. Box hood style
C. Angled hood style
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Gas Dryer
WGD9500T
WGD9600T
1"* (25 mm)
A*
* Required spacing
D
E *
C
4"
(102 mm)
2½"
(64 mm)
6"* (152 mm)
76"
*Required spacing
(1930 mm)
NOTE: Some models are not recommended for stacked
recessed or closet installation.
27"
1"
1"
(25 mm)
(25 mm)
(686 mm)
Steam
(Electric or Gas)
A
0" (0 mm)
B
38" (9652 mm)
C*
1" (25 mm)
D
27" (686 mm)
E*
1" (25 mm)
*Required spacing
NOTE: Some models are not recommended for undercounter
installation.
NOTE: Side and bottom exhaust installations have a 90º turn inside
the dryer. To determine maximum exhaust length, add one 90º turn
to the chart.
Number
Type of vent
90º elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns. Use the fewest
90° turns possible.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Steam
(Electric or Gas)
A*
5 ½" (140 mm)
Non-Steam
(Electric or Gas)
0" (0 mm)
38" (9652 mm)
1" (25 mm)
27" (686 mm)
1" (25 mm)
Box /louvered
Angled
hoods
hoods
64 ft (20 m)
58 ft (17.7 m)
54 ft (16.5 m)
48 ft (14.6 m)
44 ft (13.4 m)
38 ft (11.6 m)
35 ft (10.7 m)
29 ft (8.8 m)
27 ft (8.2 m)
21 ft (6.4 m)
Non-Steam
(Electric or Gas)
5" (127 mm)
Page 3 of 3
Ref. W10224610
11-09-08

Advertisement

loading

This manual is also suitable for:

Wgd9300vWgd9400sWgd9400vWgd9400szWgd9500tWgd9600t