Stopping ID Code Incrementing .....................29 Setting the Number of Line Feeds between Print Requests ..........29 Switch Module Command Summary ..................29 5.0 SP2200 Control Codes and Escape Sequences................30 SP2200 Control Codes ......................31 ASCII Character Set ......................32 6.0 Printer Maintenance ........................33 Routine Maintenance ......................
MM/DD/YY is the date (If US format is used. If international format is used, the date is shown in the format DD/MM/YY.) • CCCCCCCC is the ID code The SP2200 must be confi gured for weight extraction mode when connected to devices sending data as con- tin u ous output. 1.1.2 Standard Input Mode Standard input mode is used to print data exactly as received from the sending device.
1.2.5 Time and Date The time and date option provides time and date stamping for tickets printed by the SP2200. The time and date module can be programmed using the optional switch module or a serial sending device. Front Panel Indicators...
Section 2.3 to verify installation. Setup Initial setup of the SP2200 consists of installing the print ribbon, setting the head gap, and running the printer self-test. See Section 2.4 for information about installing optional equipment.
Page 10
Hole for cone-shaped tab on back of ribbon cartridge Ribbon drive gear Figure 2-2. SP2200 print mechanism, showing ribbon drive gear 3. Snap the cartridge into place, fi tting the hole in the ribbon take-up knob over the ribbon drive gear. If necessary, adjust the ribbon take-up knob to align the cartridge gear with the ribbon drive gear.
2.2.2 Setting the Head Gap The SP2200 is designed to accept forms up to a thickness of .024 inches (0.609 mm). The head gap ad just - ment lever (Figure 2-4) can be set to print up to 5-part forms. The six detents allow a head gap range of .004 to .024 inches in .004-inch increments.
RS-232, 20mA current loop, and RS-422A interfaces. Notes: 1. You must use a separate test plug for each of the interfaces used by the SP2200. A test plug wired for both RS-232 and 20mA current loop will not verify operation of the 20mA circuit.
2. Remove three screws from back of print mechanism cover (see Figure 2-8). Lift and remove cover. Print mechanism cover screws (3 ) Electronics cover screw LIN E PARALLEL INPUT SERIAL I/O Figure 2-8. Back of SP2200, showing screws for removing electronics and print mechanism covers...
Page 14
Figure 2-9. Bottom view of SP2200, showing screws for removing print mechanism 5. Set the printer upright, then remove the print mechanism. Do not disconnect cables between the print mechanism and the SP2200 circuit board. Replugging cables into the wrong connectors will result in circuit damage.
Page 15
Serial Port C1 1 Print Mechanism Ribbon Cable R1 1 CR10 F R O N T Figure 2-10. SP2200 circuit board, showing locations of optional components and connectors...
2.4.2 20mA Current Loop Interface To in stall the 20mA cur rent loop in ter face, dis con nect pow er to the print er and fol low the pro ce dure for re mov ing the cov ers as described in Section 2.4.1. Once the covers are re moved, continue with the following steps: 1.
Switch module screws (2) Figure 2-11. Bottom of SP2200, showing screws for attaching switch module 2.4.6 Time and Date Module To install the time and date module, disconnect power to the printer and follow the procedure for removing the covers and print mechanism as described in Section 2.4.1. Once the print mechanism is removed, continue with the following steps: 1.
A parallel communications interface is also available for use with host devices with parallel printer ports. Only ASCII-encoded data is supported by the SP2200. The SP2200 can be connected to host devices using other data formats, but a protocol converter must be used to convert the data to ASCII encoding before the SP2200 can process the data.
Serial Port Pin Connections Parallel Port Pin Connections The following table lists the pin connections for The following table lists the pin connections for the the SP2200 serial data input port. SP2200 parallel data input port. Signal Signal Chassis ground...
IQ plus 350/355 Indicators The SP2200 can be connected to the IQ plus 350/355 indicators at baud rates of 300 to 9600 bps. Com mu - ni ca tions cable con nec tions are made to the terminal blocks in the IQ plus 350/355 as shown in the following tables.
IQ plus 510/710 Indicators The SP2200 can be connected to the IQ plus 510 and 710 indicators at baud rates of 300 to 19200 bps. Com- mu ni ca tions cable con nec tions are made to the J4 and J5 terminal blocks in the indicators as shown in the fol low ing tables.
IQ700/UMC600 Indicators The SP2200 can be connected to the IQ700/UMC600 indicators at baud rates of 300 to 9600 bps. Com mu - ni ca tions cable con nec tions are made to the terminal blocks in the IQ700/UMC600 as shown in the following tables.
3.10 UMC444/555 Indicators The SP2200 can be connected to the UMC444/555 indicators at baud rates of 300 to 9600 bps. Com mu - ni ca tions cable con nec tions are made to the terminal blocks in the UMC444/555 as shown in the following tables.
3.11 520/920i Indicators The SP2200 can be connected to the 520/920i indicators at baud rates of 300 to 19200 bps. Com mu ni ca tions cable con nec tions are made to the terminal blocks in the 520/920i as shown in the following tables.
3.13 420 Plus Indicator The SP2200 can be connected to the 420 Plus indicator at baud rates of 300 to 19200 bps. Com mu ni ca tions cable con nec tions are made to the terminal blocks in the 420 Plus as shown in the following tables.
4.0 Confi guring the SP2200 The SP2200 is confi gured using three banks of DIP switches, labeled S1, S2, and S3, on the back of the unit. Each bank contains 8 switches, numbered 1 through 8. Switches are referred to by bank and switch number;...
3-8 should be set off to prevent accidental changes to the programmed information. This switch has no effect on the use of the PRINT button. Communications Confi guration Switches Figure 4-3 shows the DIP switches used to confi gure communications for the SP2200. These switches are described in the following sections. OFF = 0...
Switch 3-2, when set on, enables the Toledo interface mode when connecting the SP2200 to Toledo in di ca tors. This mode allows the SP2200 to communicate with Toledo indicators and to format weight information in both standard and weight extraction modes. Shift-in/shift-out (SO/SI) characters are also supported.
Table 4-3. Font selection switches 4.3.2 Form Feed Switch 1-7 controls form feed direction. When set on, this switch causes the SP2200 to reverse the feed direc- tion, pulling forms from the rear of the printer toward the front. 4.3.3 Eat <LF> after <CR>...
DIP Switch Confi guration Summary The following table summarizes the function of the SP2200 DIP switch banks. See Sections 4-1 through 4-3 for detailed information. & & & & & < > < > & n i t s t i &...
Setting the Time and Date If the time and date module is installed in the SP2200, you can set the time and date using either the switch module (if installed) or a serial input device such as a PC or ASCII terminal.
Setting ID Codes If the switch module is installed in the SP2200, you can enter ID codes to be printed with weight data when the printer is in weight extraction mode. ID codes must be 8 digits in length and use only the digits 0 through 9 and the fol low ing char ac ters: colon, period, and space.
Example: To enter a constant ID code of 487561, you would enter the following characters, pressing the SET button after each character. The ID code entered must be eight characters in length. Use leading zeroes or spaces for codes of less than eight characters. In the example below, the C characters are used to insert two spaces before the ID code.
Example 2: You can set an ID code to increment from any value entered as a constant ID code. For example, to set the SP2200 to increment through values of 100 to 99999, do the fol low ing: 1) Enter the starting value as a constant ID code: Because the starting value is also incremented, you must enter a value of one less than the fi...
Switch Module Command Summary The following table provides a summary of switch module command formats used to set the time and date, ID codes and the number of line feeds between print requests. See Sections 4-4 through 4-6 for detailed de scrip - tions of switch module commands.
<ESC> command code followed by the alternate command. For IBM-compatible devices, the escape sequence consists of the key combination for the <ESC> command code (Ctrl-[) followed by a one-character alternate command. The following table lists the alternate command used by the SP2200: Command Command Description...
The following table shows the key combinations used by IBM-compatible devices to enter control codes for the SP2200. The table lists the decimal and hexa dec i mal values of the control codes, ASCII character des ig - na tion, and the command issued to the SP2200 by the control code.
Fuse Replacement If the SP2200 will not power on, use the following procedures to check the line fuses, power supply fuse, then the 5 volt supply fuse on the CPU board. 6.3.1 Line Fuses To replace line fuses in the SP2200, do the following: 1.
6.3.2 AC Power Supply Current Limiting Fuse The SP2200 uses a 5A fuse to limit current output of the power supply. If the line fuses are good but the SP2200 does not power up when connected to the power source, use the fol low ing procedure to check the power supply fuse: 1.
7.0 SP2200 Specifi cations Electrical Specifi cations Voltage: 115 or 230 VAC (–10% / +15%) Frequency: 50 or 60 Hz Fusing: Two 1.25A Slo-Blo (UL/CSA) 3AG @ 115 VAC operation, or Two 0.75A Slo-Blo (UL/CSA) 3AG @ 230 VAC operation (line fi lter) One 125V/5.0A fast-acting, socketed (UL/CSA) microfuse (power supply)