Service codes

4
Service codes
Service code
S-00
Setting of the
connected devices
S-01
Output voltage
S-02
Output frequency
S-03
Standby mode
S-04
Standby timer
S-05
Standby delay
S-06
Standby threshold
S-07
DC high-voltage
shutdown
S-08
Upper DC restart
voltage
S-09
DC low-voltage
shutdown
S-10
lower DC restart
voltage
S-11
Advance warning
setting
S-12
Battery type
S-13
Battery capacity
S-14
Battery charging
current
6
Description
only battery sensor MCA-HS1
only MCA battery charger
Battery sensor MCA-HS1 and MCA bat-
tery charger
only DSP-T inverter
Battery sensor MCA-HS1 and
DSP-T inverter
MCA battery charger and DSP-T inverter 6
Battery sensor MCA-HS1, MCA battery
charger and DSP-T inverter
DSP-C inverter
Battery sensor MCA-HS1 and
DSP-C inverter
Sets the output voltage of the inverter.
Sets the frequency of the output voltage. 50 Hz or 60 Hz
Switches standby mode ON/OFF.
Sets the time in standby mode after
which the inverter switches off.
Sets the time after which the inverter
switches to standby mode if no load is
present.
Sets the power at which the inverter is
activated from standby mode.
Sets the upper voltage value at which
the inverter switches off.
Sets the voltage at which the inverter
switches on again after a high-voltage
shutdown.
Sets the lower voltage value at which the
inverter switches off.
Sets the voltage at which the inverter
switches on again after a low-voltage
shutdown.
Sets the value from which an imminent
switch off is displayed.
Sets the battery type.
Sets the capacity of each battery sensor. 10 Ah to 249 Ah
Sets the maximum battery charging
current, as a percentage of the rated
charging current.
Stand
Range
ard
value
1
3
2
3
4
5
7
8
9
230 V or 240 V
230 V
50 Hz
ON, OFF
ON
OFF, 5 min to 30 min
20 min
in 5 min intervals,
1 h to 24 h
in 1 h intervals
10 s, 1 min to 10 min
10 s
OFF, 1 W, 5 W to 45 W
1 W
15 V to 16.5 V
16.5 V
in 0.1 V intervals
no recovery,
15.5 V
13 V to 16.4 V
in 0.1 V intervals
10 V to 11.5 V
10.5 V
in 0.1 V intervals
no recovery,
12.5 V
10.1 V to 14.5 V
in 0.1 V intervals
OFF,
0.5 V
0.1 V to 2.0 V
in 0.1 V intervals
0: Lead acid
0
1: Gel
2: AGM
3: eStore
4: Custom
100 Ah
25 %, 50 %, 75 %,
50 %
100 %
DSP-EM
Device
Display
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
DSP-T, DSP-C
IBS and IBS
multiplexer
IBS and IBS
multiplexer
DSP-C