Download Print this page

Hoshizaki KMD-410MAH Cleaning & Sanitizing page 2

Hide thumbs Also See for KMD-410MAH:

Advertisement

Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep
KMD-460 & 530M_H:
Loosen the two thumbscrews on the pump insulation
panel (B) and remove the panel.
Disconnect the discharge hose, the drain valve hose,
and the overflow drain hose.
Disconnect the pump motor and then the float switch
connectors from the control board.
Remove the two thumbscrews securing the pump
motor and float switch assembly.
Pull out the water tank, cube guide, and pump motor
and float switch assembly all together.
Remove the screw securing the float switch to the
top of the assembly, remove the float switch*.
See Step
for cleaning steps. Reassemble in the
reverse order they were removed.
* Remove retainer rod (take care not to bend excessively) from bottom of the float switch housing & clean all float parts.
8
Replace all the Panels, except the Front Panel.
Move the
service switch
switch
to SERVICE. Replace the Front Panel.
9
After 30 minutes, remove the Front Panel, move
the
service switch
to DRAIN. Replace the Front
Panel.
ATTENTION! To prevent damage to the water pump,
do not leave the control switch on SERVICE for
extended periods when water tank is empty.
Cleaning Rinse:
10
After 2 minutes, remove the Front Panel, move the
the Front Panel.
11
After 3 minutes, move the
SERVICE. Replace the Front Panel.
12
After 5 minutes, remove the Front Panel, move the
Replace the Front Panel
13
After 2 minutes, remove the Front Panel, move the
14
Repeat 3x (Steps
on front...
After
After
3 min.
2 min.
#51009 | 4.28.2017
KMD-410M_H:
Loosen the two thumbscrews securing the
pump motor bracket.
Disconnect the discharge hose.
Disconnect the pump motor and float switch
connectors from the side of the control box.
While pushing up on the snap tab, pull out the
water tank, cube guide, pump motor bracket,
and pump motor and float switch assembly all
together.
Remove the pump motor bracket securing the
float switch to the top of the assembly, remove
the float switch*.
See Step
the reverse order they were removed.
to WASH, and the
control
service switch
to WASH, and the
thru ⓭) to rinse thoroughly. Continue to Sanitation – Step
After
5 min.
Tech Support: 1.800.233.1940
for cleaning steps. Reassemble in
After
30 min.
control switch
to ICE. Replace
control switch
to
service switch
to DRAIN.
control switch
to OFF.
After
Repeat
3 min.
 sanitizing continued...
RINSE 1:
(Steps 20-22)
• Move
control switch
replace front panel
• After 3 minutes, remove the
front panel
• Move
service switch
and
control switch
replace the front panel
• After 5 minutes, remove the
front panel
• Move
service switch
replace the front panel
• After 2 minutes, remove
the front panel
• Move
control switch
replace the front panel
RINSE 2:
• Repeat RINSE 1 (Steps 20–22)
for complete ice/food safety
• Clean the dispenser unit /
ice storage bin liner with a
neutral cleaner (dish soap)
• Rinse thoroughly
• Move
control switch
replace front panel
ATTENTION!
IF ICEMAKER IS ON DISPENSER,
remember to turn on the dispenser
after cleaning
DO NOT use ammonia type cleaners
WEAR liquid-proof gloves and goggles
to protect skin & eyes from cleaning &
sanitizing chemicals
AMMONIA
Cleaners
Scoop
Dish soap, rinse well
Water Filters
Check psi, change if req'd
Exterior
Dish soap & damp cloth
Bin Door/Top Kit
Warm water & clean cloth
Icemaker/Bin
Follow these instructions
Water Supply Inlet
Clean inlet screen
Condenser
Inspect. Clean with brush
3x
Water Hoses
Inspect. Replace if req'd
20
to ICE,
to WASH
to SERVICE,
21
to DRAIN,
22
to OFF,
23
24
25
to ICE,
Page 2

Advertisement

loading

This manual is also suitable for:

Kmd-410mwhKmd-410mrhKmd-460mahKmd-460mwhKmd-460mrhKmd-530mah ... Show all