Viessmann VITOCELL 100-V Installation And Service Instructions Manual page 6

Dhw cylinders, 160 l to 300 l
Table of Contents

Advertisement

Information
Intended use
(cont.)
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and results in an exclusion of liability.
Incorrect usage also occurs if the components in the
system are modified from their intended use (e.g.
through direct DHW heating in the collector).
Product information
Vitocell 100-V/100-W, types CVAA, CVAB-A
Vertical DHW cylinder with internal indirect coil. Cylin-
der and internal indirect coil made from steel, corrosion
protection through Ceraprotect enamel coating and
protective magnesium anode. The DHW cylinders fea-
ture all-round thermal insulation enclosed within an
epoxy-coated sheet steel casing.
Inspection and maintenance
DIN 1988 requires a visual inspection and (if neces-
sary) cleaning no later than 2 years after the cylinder
has been commissioned, and thereafter according to
requirements.
System examples
Available system examples: See www.viessmann-
schemes.com.
Spare parts lists
Information about spare parts can be found at
www.viessmann.com/etapp or in the Viessmann
spare part app.
6
Adhere to statutory regulations, especially concerning
the hygiene of potable water.
Suitable for systems conforming to DIN 1988,
EN 12828 and DIN 4753.
Vitocell 100-V: Vitosilver
Vitocell 100-W: White
Note
We recommend checking the function of the protective
magnesium anode annually. This check can be carried
out without interrupting operation. The earth current is
tested with an anode tester (see page 20 20).