Battery operated photoelectric detector power convertor unit

Advertisement

SYSTEM DIAGRAM
Transmitter
Back box
PCU-5
Battery plate
* UNUSED
The DQ function is not provided
with the SL-TNR.
Do not insert batteries into the unit
which is operated by PCU-5.
Warning
Doing so may result in fire or explosion.
FUNCTION TO TRANSMIT LOW-BATTERY
SIGNAL
The low-battery signals are transmitted from the transmitter
using IR beams.This function enables to eliminate the need
to install a wireless transmitter in the transmitter.
Low battery signal
Transmitter
* Even if the receiver is powered by PCU-5, low-battery wiring
is required to report the low-battery status of the transmitter.
DIMENSIONS
20 (0.8)
71 (2.8)
www.GateOpenerSafety.com | (800) 878-7829 | Sales@GateOpenerSafety.com
Receiver
Main unit
Red
Black
from PCU-5
Control panel
10 - 30V
Low battery
Tamper
* Receiver
Control
panel
Unit: mm (inch)
Back box
Battery plate
PCU-5
PCU-5
Power
+
Power
C
Alarm
Alarm
NC
NO
C
DQ*
DQ*
NC
NO
C
Low battery
NC
C
Tamper
NC
WIRING DISTANCE BETWEEN POWER
SUPPLY AND DETECTOR
Wire size
2
0.33mm
(AWG22)
0.52mm
2
(AWG20)
0.83mm
2
(AWG18)
2
1.31mm
(AWG16)
SPECIFICATIONS
Power input
Current draw
Output voltage
Output current
Alarm output
D.Q. output
Low battery output
Tamper output
Operating temperature
Operating humidity
Dimension
-2-
+
C
NC
C
UNUSED
NC
C
NC
C
NC
Power supply voltage
12VDC
180m (600ft.)
280m (900ft.)
450m (1,500ft.)
700m (2,300ft.)
10.5 - 30 VDC
80mA (max.)
Approx. 3.9 VDC
10mA (max.)
Form C relay ; 30VDC. 0.2A
Unused (Form C relay ; 30 VDC 0.2 A)
N.C. relay ; 30VDC. 0.2A
N.C. relay ; 30VDC. 0.2A
-20°C to 60°C (-4°F to 140°F)
95% (max.)
H×W×D mm (inch): 71 (2.8) × 53 (2.1) × 20 (0.8)
Main unit
Red
Black
Y ellow
Orange
Brown
Green
Blue
Purple
Gray
24VDC
1,200m (4,000ft.)
1,800m (6,000ft.)
3,000m (10,000ft.)
4,500m (14,500ft.)