4-5-2. Service Function
Checking the Code Version
1.
Enter the service mode, and check the MCU code version and checksum.
2.
Entering the Service Mode
Adjust the brightness and contrast ratio to 0.
-
Press and hold the Enter button for about 5 seconds.
-
The SVC Function screen will be displayed.
-
To close SVC Function, turn the power off.
-
3.
Safe Mode
If the input signal is higher than the frequency supported by the product, the safe mode will turn the graphics card
-
setting to recommended mode for about 1 minute.
Service Function
Monitor On Time :
Panel
Ch. No. :
On Time :
Cycle
Auto Auto
Pixelshift
Country
Scaler-MCU
Version
: m-S119N0GFa-0900.0
Checksun : FE95
0 Hr
0
0 Hr
:
10
:
On
:
Off
:
English
: Novatek NT68650
Panel Information
Select the Auto option
Select the PixelShift option.
Country
Scaler Vender
Micom Version
Micom Checksum
4. Troubleshooting