Belimo UK24BAC Technical Data Manual
Belimo UK24BAC Technical Data Manual

Belimo UK24BAC Technical Data Manual

Belimo gateway mp to bacnet ms/tp

Advertisement

Quick Links

www.belimo.com
Product information
BACnet MS/TP
Belimo Gateway
MP to BACnet MS/TP - UK24BAC
Contents
T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes
UK24BAC
2
3
4
4
4
5
7
8
11
13
15
16
1 / 20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UK24BAC and is the answer not in the manual?

Questions and answers

Summary of Contents for Belimo UK24BAC

  • Page 1: Table Of Contents

    Installation and commissioning Electrical installation Dimensions Operation Protocol Implementation Conformance Statement - PICS BACnet object description Connecting the PC-Tool for parameterisation of the MP/MFT(2) actuators Version overview T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 1 / 20...
  • Page 2: Complete Overview

    Suitable MP/MPL/MFT(2) Actuators Damper actuators Fire damper actuators VAV actuators Actuators for characterised control valve, butterfly valves 2-way EPIV actuators and globe valves MPL actuators T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 2 / 20 www.belimo.com...
  • Page 3: Technical Data

    Installation / Dimension / Weight Mounting Control cabinet installation, can be snapped onto top hat rail 35 mm Dimensions see page 7 Weight ca. 100 g T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 3 / 20...
  • Page 4: Safety Notes

    Product features Mode of operation The UK24BAC allows the actuators to be controlled digitally via the MP-Bus and send back their current operating status. The control system information and the response is administered in BACnet objects in the UK24BAC and can be processed with BACnet services. This permits the actuator functions to be integrated directly into BACnet.
  • Page 5: Electrical Installation

    MP/MPL/MFT(2) actuators [VA] Power rating [VA] For the calculation of the maximum cable length, the Belimo MP wiring calculator is available on the Belimo website for the complete MP-Bus range. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com...
  • Page 6 DC supply (minimum supply voltage DC 24 V) For the calculation of the maximum cable length, the Belimo MP wiring calculator is available on the Belimo website for the complete MP-Bus range. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 6 / 20 www.belimo.com...
  • Page 7: Dimensions

    Total power rating 3.5 W + 4 W + 3 W + 3 W = 13.5 W [mm²] 0.75 1.00 1.50 2.50 Dimensions Dimensional drawings [mm] T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 7 / 20...
  • Page 8: Operation

    Setting the BACnet MAC address The valid address range is 1-127. Values outside of this range will be interpreted as either 1 or 127, respectively. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 8 / 20 www.belimo.com...
  • Page 9 4. Download of firmware according to special instruction 5. Remove USB cable 6. Set DIP switch 4 "Programming" to OFF 7. Connect power supply to device T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 9 / 20...
  • Page 10 All non-volatile BACnet properties will be restored to factory default by pressing the OK button Restore of Factory Settings for more than 3 seconds while the device is starting. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 10 / 20 www.belimo.com...
  • Page 11: Protocol Implementation Conformance Statement - Pics

    1.10 Product Description: The UK24BAC device is a gateway from MP to BACnet MS/TP. Up to eight MP-bus-capable Belimo actuators can be connected on the MP-Bus side. This permits the actuator functions as well as the connected sensors to be integrated directly into BACnet.
  • Page 12  The properties Object_Name, Description and Location of the Device Object support up to 64 characters (all other character strings are read-only).  The device does not support the CreateObject and DeleteObject service. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 12 / 20 www.belimo.com...
  • Page 13: Bacnet Object Description

    120 seconds. If the override command is not renewed, then the Gateway will move the actuator into safety position (Relinquish_Default is not writable). T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 13 / 20...
  • Page 14 Initiation of actuator functions for TEST maintenance and test; the selected RESET command is transmitted to the actuator, after which the Present-Value will be reset to NONE. T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 14 / 20 www.belimo.com...
  • Page 15: Connecting The Pc-Tool For Parameterisation Of The Mp/Mft(2) Actuators

    The PC -Tool can be accessed directly on the MP-Bus via the RJ12 socket of the UK24BACMOD. The Gateway recognises the connected PC-Tool automatically and stops communications with the MP drives. ZK6-GEN Belimo PC-Tool MP-Bus T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 15 / 20...
  • Page 16: Version Overview

     WritePropertyMultiple service not supported  Engineering units (position and volumetric flow) not for all actuator types updated  Unsolicited-COV-Reporting for volumetric flow not supported T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 16 / 20 www.belimo.com...
  • Page 17 UK24BAC Belimo Gateway MP to BACnet MS/TP T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 17 / 20...
  • Page 18 UK24BAC Belimo Gateway MP to BACnet MS/TP T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes 18 / 20 www.belimo.com...
  • Page 19 UK24BAC Belimo Gateway MP to BACnet MS/TP T9-UK24BAC • en • v1.9 • 06.2018 • Subject to changes www.belimo.com 19 / 20...

Table of Contents