JP Tech 290-TIME-1 User Manual

Time based meters pump controllers

Advertisement

Quick Links

MODELS
B. Model Overview
IV. APPENDIX
Check for the latest manual updates at
JP Tech, Inc. • PO Box 863 • 2286 Church Street • East Troy • WI • 53120
TIME BASED METERS
PUMP CONTROLLERS
290-TIME-1
290-TIME-P1
CONTENTS
Phone: (262) 642-7671 • Fax (262) 642-7681
USER MANUAL
290-TIME-P3
JPTech.com
2
2
3
4
4
5
5
6
7
8
9
9
10
REVISED 6/30/16
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 290-TIME-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for JP Tech 290-TIME-1

  • Page 1: Table Of Contents

    A. Maintenance B. Parts List REVISED 6/30/16 Check for the latest manual updates at JPTech.com JP Tech, Inc. • PO Box 863 • 2286 Church Street • East Troy • WI • 53120 Phone: (262) 642-7671 • Fax (262) 642-7681...
  • Page 2: Installation

    INSTALLATION Step-by-Step Guide 1. Read Manual to familiarize yourself with the operation of the meter. 2. Mount Unit. FOR PUMP (P) MODELS: Attach feed tubes to the Squeeze tubes using wire ties or stainless hose clamps. NOTE: Pick up tube may float so you might need to weigh it down.
  • Page 3 INSTALLATION TIME-P1 Model PUMP OUTPUT (Only in Pump Control Versions) The TIME-P1 models come with two 120 VAC pigtails with female receptacles. Any 120 VAC pump which draws no more than five amps can be plugged into these receptacles. When the preset number of seconds is attained, the pump will be energized for the length of time that the 120 VAC POWER...
  • Page 4: Quick Start

    JP Tech’s Time Based meters are designed for measuring accumulated seconds. TIME-P1 and TIME-P3 models of the Time Based meters can also control two (2) pumps. JP Tech’s Time Based meters incorporate a simple menu design featuring a two (2) button keypad. Pressing the SELECT key once cycles through different menu screens.
  • Page 5: Menu Operation

    MENU OPERATION Menu Hierarchy 1. One Shot Count (Default Screen if One Shot Mode is enabled) 1. Cumulative Second Total (Default Screen) 2. Resettable Second Total 3. Prime Pump (if either pump is enabled) IF PUMP 1 IS ENABLED 4. Preset 1 5.
  • Page 6: Main Menu Screens

    MENU OPERATION Main Menu Screens NOTE: The status of the meter is indicated in the lower right hand corner. OFF indicates that the counters are off, and ON that the counters are on. (P Models Only): If pumps are enabled, P1 (pump 1), P2 (pump 2), or P12 (pumps 1 and 2) will appear.
  • Page 7: Pump Controls (For P Models Only)

    MENU OPERATION Pump Controls (P models only) 4. PRESET 1 / 9. PRESET 2 PRESET1 This screen is used to set the interval of seconds before 000000 the pump is turned on. The pump will activate for the length of time (in seconds) specified in the corresponding TIMER.
  • Page 8: Setup Options

    MENU OPERATION Setup Options 14.1 RELAY 1 / 14.2 RELAY 2 RELAY1 This screen is used to select what kind of device you are controlling. You can choose between a PUMP or to DISABLED DISABLE one or both of the relays. Enabling either of the relays will allow access to the corresponding PUMP and TIMER menus.
  • Page 9: Maintenance

    MAINTENANCE The PERISTALTIC Series of metering pumps require a minimal amount of maintenance to achieve optimal performance. Periodically check the squeeze tube for cracks, deterioration, or swelling. The squeeze tube will typically need to be replaced about every 6 months (chemical compatibility and duty cycle can cause this interval to vary).
  • Page 10: Parts List

    PICK UP TUBE 245-4-PICKUP NOTE: CHECK YOUR SQUEEZE TUBES PERIODICALLY FOR INTEGRITY (ABLE TO EXPAND AFTER BEING SQUEEZED BY THE ROLLERS). ORDER PARTS PHONE: 262-642-7671 FAX: 262-642-7681 E-MAIL: sales@jptech.com MAIL: JP TECH, INC. P.O. Box 863 East Troy, WI 53120 WEB: JPTech.com...
  • Page 11 This warranty may be modified, wholly or in part, at any time by JP Tech without notice to past or future customers. The warranty revision in effect at the time of shipment shall prevail in any claims rendered.

This manual is also suitable for:

290-time-p1290-time-p3

Table of Contents