Evco Vcolor EPV4CBR Hardware Manual
Evco Vcolor EPV4CBR Hardware Manual

Evco Vcolor EPV4CBR Hardware Manual

Programmable remote user interfaces, with color touch-screen tft graphic display

Advertisement

Quick Links

EVCO S.p.A.
Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104
Vcolor
Programmable remote user interfaces, with
color touch-screen TFT graphic display
Hardware manual | ENGLISH
Code 144VCOE104
page 1 of 38

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vcolor EPV4CBR and is the answer not in the manual?

Questions and answers

Summary of Contents for Evco Vcolor EPV4CBR

  • Page 1 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Vcolor Programmable remote user interfaces, with color touch-screen TFT graphic display Hardware manual | ENGLISH Code 144VCOE104 page 1 of 38...
  • Page 2 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Important Read this document thoroughly before installation and before use of the device and follow all recommendations; keep this document with the device for future consultation. Only use the device in the way described in this document; do not use the same as a safety device.
  • Page 3: Table Of Contents

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Index INTRODUCTION ..........4 Introduction ............ 4 Summary table of the available models, the main features and the purchase codes......5 SIZE AND INSTALLATION ......... 6 Size ............... 6 Panel mounting ..........
  • Page 4: Introduction

    The interfaces can easily be integrated both in residential and in commercial environments; at their front it is possible to apply the frontal plates CPVP EVCO (to order separately) or the plates belonging to the series "Living" and to the series "Light"...
  • Page 5: Summary Table Of The Available Models, The Main Features And The Purchase Codes

    • alarm and signalling buzzer • For further information look at chapter 10 “TECHNICAL DATA”. The following table shows the purchase codes. Purchase codes: EPV4CBR For further information contact the EVCO sales network. page 5 of 38...
  • Page 6: Size And Installation

    Through the gasket 0027000007 (to order separately) it is possible to guarantee a protection rating IP65; through the frontal plates CPVP EVCO (to order separately) or the plates belonging to the series "Living" and to the series "Light" BTicino it is possible to integrate the devices both in residential and commercial environments.
  • Page 7: Built-In Mounting

    It is necessary to install the box vertically. Through the frontal plates CPVP EVCO (to order separately) or the plates belonging to the series "Living" and to the series "Light" BTicino it is possible to integrate the devices both in residential and commercial environments.
  • Page 8: Wall Mounting

    The following drawing shows the wall mounting of the devices (in wall mounting support CPVW00 EVCO, to order separately). Through the frontal plates CPVP EVCO (to order separately) or the plates belonging to the series "Living" and to the series "Light"...
  • Page 9: Wiring Diagram

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 WIRING DIAGRAM Connectors The following drawing shows the connectors of the devices. Meaning of connectors The following tables show the meaning of the connectors of the devices. CANBUS CAN port CAN port with CANBUS communication protocol.
  • Page 10: Plugging-In The Line Termination Of The Rs-485 Network With Modbus Communication Protocol

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 The following table shows the Function codes supported by the device, on condition that it works in commander modality and the communication protocol is MODBUS. Function code Meaning FC 01...
  • Page 11: Network With Canbus Communication Protocol

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Plugging-in line termination network with CANBUS communication protocol To reduce the reflections on the signal transmitted along the cables connecting the devices to a CAN network with CANBUS communication protocol it is necessary to plug-in the line termination of the first and of the last element of the network.
  • Page 12: Example Of Wiring Diagram

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Example of wiring diagram The following drawing shows an example of wiring diagram of the devices. page 12 of 38...
  • Page 13: Additional Information For Wiring Diagram

    CAN network with CANBUS communication protocol using a twisted pair connect the power cables the most possible away from the signal’s ones for repairs and information on the device please contact the EVCO’s sales network. page 13 of 38...
  • Page 14: Descritpion

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 DESCRITPION Description of the front The following drawing shows the aspect of the front of the devices. The following table shows the meaning of the parts of the front of the devices.
  • Page 15: Description Of The Back

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Description of the back The following drawing shows the aspect of the back of the devices The following table shows the meaning of the parts of the back of the devices.
  • Page 16: First Use

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 FIRST USE First use Operate as follows: Make the installation of the device with the modality shown in chapter 2 “SIZE AND INSTALLATION” following all the additional information related in paragraph 3.7 “...
  • Page 17: Preliminary Information

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 PRELIMINARY INFORMATION Switching on/off the device To switch on the device, operate as follows: Connect the power supply: i twill be started an internal test. The test takes typically a few seconds.
  • Page 18: Configuration

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 CONFIGURATION Setting the date and the time According to the factory settings the date is shown in the format dd mm yy and the time in the format 24 h.
  • Page 19: Setting The Language For Showing (If Foreseen) The

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Setting language showing foreseen) words of the application project To set the language for showing (if foreseen) the words of the application project, operate as follows: Switch on the device and show the sensitive areas;...
  • Page 20: Setting The Configuration Parameters Of The Menu

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 To quit the procedure, operate as follows: Press and release over and over again the area “ESCAPE”. Switch off/on the power supply of the device after the parameters setting.
  • Page 21: Parameters

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Uploading and downloading the configuration parameters 7.5.1 Uploading the configuration parameters The upload of the configuration parameters can be done on condition that the firmwares coincide. To make the upload of the configuration parameters, operate...
  • Page 22 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Press and release the area “ENTER”: it will be started upload configuration parameters. The upload takes typically a few seconds; if the operation is not completed succesfully, the display will show an error indication (for example “Status:...
  • Page 23 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Press and release the area “DOWN” to select “Save on USB” or “Save on memory” (according to the option selected in step 9). Press and release the area “ENTER”: it will be...
  • Page 24: Configuring An Element Of A Can Network With

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Configuring an element of a network with CANBUS communication protocol To configure an element of a CAN network with CANBUS communication protocol, operate as follows: Disconnect the power supply of the device and of the other element of the network.
  • Page 25: List Of The Configuration Parameters

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 List of the configuration parameters 7.7.1 Configuration parameters of the menu “Info” The following table shows the meaning of the configuration parameters of the menu “Info”. PARAM. MIN. MAX.
  • Page 26 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 7.7.3 Configuration parameters of the menu “Parameters” The following table shows the meaning of the configuration parameters of the menu “Parameters”. PARAM. MIN. MAX. U.M. DEF. DESCRIPTION Date Char...
  • Page 27 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 kind of beep when pressing a sensitive area of the display of the device Beep Mode - - - no beep always on condition the area is sensitive showing frames instead small size pages...
  • Page 28 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Press and release key “RIGHT” to show the section “CAN Status” of the submenu “CAN bus” of the menu “Networks” . PARAM. MIN. MAX. U.M. DEF. DESCRIPTION Cnt Rx...
  • Page 29 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 7.7.5 Configuration parameters of the submenu “UART” of the menu “Networks” The following table shows the meaning of the configuration parameters of the submenu “UART” of the menu “Networks”.
  • Page 30 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 7.7.7 Configuration parameters of the menu “Diagnostics” The following table shows the meaning of the configuration parameters of the menu “Diagnostics”. PARAM. MIN. MAX. U.M. DEF. DESCRIPTION status of the non volatile memory...
  • Page 31: Signals

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 SIGNALS Signals The following tables shows the meaning of the LED of the device. LED colour Meaning LED power supply device green if it is lit, the device will be powered...
  • Page 32: Accessories

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 ACCESSORIES Connecting cables 0810500018/0810500020 9.1.1 Preliminary information Through the cables it is possible to make more accessible the USB port of the devices. The cable 0810500018 is 2.0 m long; the cable 0810500020 is 0.5 m long.
  • Page 33: Gasket 0027000007

    EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 Gasket 0027000007 9.4.1 Preliminary information Through the gasket it is possible to guarantee an IP65 protection rating in case of panel mounting. page 33 of 38...
  • Page 34: Technical Data

    (in box like “506e” BTicino and self-threading screws) Mounting: by wall (in wall mounting support CPVW00 EVCO, to order separately and with self-threading screws). Protection rating: IP40 (IP65 in case of panel mounting with gasket 0027000007, to order separately).
  • Page 35 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 24 VAC (±15%), 50 / 60 Hz (±3 Hz), 3 VA max not isolated 24 VDC (-15%, +65%), 2 W max not isolated supplied by a class 2 circuit.
  • Page 36 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 page 36 of 38...
  • Page 37 Vcolor Programmable remote user interfaces, with colour touch- screen TFT graphic display Hardware manual ver. 1.0 PT - 38/13 Code 144VCOE104 This document belongs to EVCO; EVCO does not take any responsibility about possible mistakes related. customer (OEM, installer final...
  • Page 38 EVCO S.p.A. Vcolor | Hardware manual ver. 1.0 | Code 144VCOE104 EVCO S.p.A. Via Feltre 81, 32036 Sedico Belluno ITALY Phone +39/0437/8422 | Fax +39/0437/83648 info@evco.it | www.evco.it page 38 of 38...

Table of Contents