Engineering Solutions Omniguard 4 Manual

Differential pressure recorder (with dual usb ports)
Hide thumbs Also See for Omniguard 4:

Advertisement

Quick Links

Introduction ............................................................................................ 2
Section 1: Basic Care ............................................................................ 4
Section 2: Navigating The LCD Display ................................................ 5
Section 3: Quick Setup & Usage ........................................................... 6
Sample Session: Viewing/Changing Settings .......................... 6
Hanging the Omniguard 4 .............................................................. 7
Display Modes................................................................................ 7
Loading the Thermal Printer Paper ................................................ 8
Section 4: Detailed Operation ................................................................ 9
Work Area Setup ............................................................................ 9
Power-Up ...................................................................................... 9
Contractor Name ............................................................................ 10
Date & Time ................................................................................... 11
Alarm Setpoint Selection ................................................................ 11
Example of Setting Alarm Levels ............................................. 12
Starting/Ending A Job ..................................................................... 12
Alarm Condition.............................................................................. 13
Alarm Silence, Disable and Rearming ........................................... 14
Turning Printer On/Off .................................................................... 14
Viewing/Printing Jobs & the Print Job Key ..................................... 14
Example of Typical Job Printout .............................................. 15
Example of Job Summary Printout .......................................... 15
Configuration Report ...................................................................... 16
Print/Log Rates .............................................................................. 16
Inlet Pressure Response Rate ....................................................... 17
Display Contrast & Backlight .......................................................... 17
Pressure Units................................................................................ 20
Passcode Protect ........................................................................... 20
Zero Calibration.............................................................................. 21
Using Help...................................................................................... 21
USB Ports ...................................................................................... 21
USB Port Status Symbols ........................................................ 22
Communication .............................................................................. 22
Transferring a Job Log to the PC ............................................. 23
USB Flash Drive - Data Collection ................................................. 23
Remote Auxiliary Alarm Setup & Usage ......................................... 24
WiFi Adapter & Off-Site Monitoring ................................................ 24
Telephone Autodialer Setup & Usage ............................................ 25
Message Rate ................................................................................ 25
Remote Monitoring & Telephone Modem Setup ............................ 27
Communication Remote Monitoring Screen ............................ 29
Appendix A: Troubleshooting ................................................................. 30
Shipping & Repair .................................................................... 31
Appendix B: Specifications .................................................................... 32
Appendix D: Limited Warranty ............................................................... 35
Engineering Solutions Inc
Contents
P/N OG4-MAN.130
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Omniguard 4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Engineering Solutions Omniguard 4

  • Page 1: Table Of Contents

    Section 2: Navigating The LCD Display ..........5 Section 3: Quick Setup & Usage ............6 Sample Session: Viewing/Changing Settings ......6 Hanging the Omniguard 4 .............. 7 Display Modes................7 Loading the Thermal Printer Paper ..........8 Section 4: Detailed Operation ..............9 Work Area Setup ................
  • Page 2: Introduction

    • 1 Year Limited Warranty. Owner’s Manual Overview Accessories This manual covers the setup and operation of the Omniguard 4. It • WiFi Adapter alerts off-site personnel via email of all job site uses several different fonts and other special characters to make conditions, including when normal operation is reached and if an various unit functions and types of reporting easy to identify.
  • Page 3: Section 1: Basic Care

    Function � setting � Name(s) ������ �������� • Be sure to plug your Omniguard 4 into a power supply that Setting being changed (edited) Info Box ���������������������� complies with the National Electrical Code. Keep all connections ������������������� dry. As with any electrical device, this unit has the potential to ��������������������������...
  • Page 4: Section 3: Quick Setup & Usage

    3. Press the POWER ON/OFF key to turn the unit on. Set the correct Time & Date if prompted. (This happens if the internal battery The Omniguard 4 can be hung on a wall for easy viewing and to has died and the built-in clock lost its settings. Don’t worry, the keep it off of the floor, away from possible damage.
  • Page 5: Loading The Thermal Printer Paper

    Power-Up To begin operating the Omniguard 4, plug the power cord into a standard wall outlet supplying 115VAC, 60Hz and press the POWER ON/OFF key. The first time a new unit is turned on the settings will be at default values.
  • Page 6: Contractor Name

    (See Pressure Units.) Contractor Name Alarm 1: (default is -0.025”WC) The Omniguard 4 can store the name of the Contractor that is using • upper setpoint of operating window the unit. The Contractor name will appear in all Job logs and printed Alarm 2: (default is -0.100”WC)
  • Page 7: Example Of Setting Alarm Levels

    3. Use the key move to the next character to set. the time followed by the pressure reading. 4. When the entire name has been entered, press SAVE to save the Page 12 Page 13 Omniguard™ 4 Owner’s Manual Engineering Solutions Inc...
  • Page 8: Alarm Silence, Disable And Rearming

    ____________________ Johnson Bldg CONTRACTOR: JOB START: Acme Abatement 10-26-08 05:38 The Omniguard 4 provides a printout of all recorded data, alarm ____________________ JOB END: SUPERVISOR: 11-01-08 17:09 messages and changes in operational settings. The current Job or TIME IN NORMAL OP:...
  • Page 9: Configuration Report

    Configuration Report Inlet Pressure Response Rate The Omniguard 4 provides a report of all the unit’s current settings This setting determines how quickly the unit will react to pressure (Alarm Setpoints, Log Rates, etc.) and the current system information changes. Reduce this setting if you are using the unit in conditions (memory status, unit serial number, etc.).
  • Page 10: Description Of Controls (Drawing Of Front Panel)

    DISPLAY HELP SILENCE FEED ON/OFF ENGINEERING SOLUTIONS INC SEATTLE, WA USA Printer Keys Special Purpose Keys PRINTER ON/OFF - turns the printer on and off. Printer status is ALARM SILENCE - silences the internal buzzer (and Remote Aux Alarm if indicated by the printer symbol at the Monitor Screen.
  • Page 11: Pressure Units

    5. Press to move from one digit to the next. The Omniguard 4 now has two USB ports. The top port, labeled USB supports the following devices: 6. Press SAVE to save the updated settings and return to the Main Menu.
  • Page 12: Usb Port Status Symbols

    The Job Logs stored in the Omniguard 4’s memory are copied as a The Omniguard 4 has built-in USB ports to connect to a PC or to a user single Log file to a USB Flash Drive. The Omniguard Communication supplied external serial modem.
  • Page 13: Remote Auxiliary Alarm Setup & Usage

    Job Log file created on the flash drive. The file name The WiFi Adapter is configured by using the Omniguard will consist of the last 6 digits of the Omniguard 4 serial number Communication software (available free at engsolinc.com). You can followed by a letter(s).
  • Page 14: Wireless Communication Using A Cellular Wireless Modem

    CELL # 2. Again use ▲/▼ to change the Omniguard 4 can store up to four Notify Lists, only one can be active first digit of the phone number. Once the first digit of the number at a time. A Notify List contains a list of wireless phone numbers and has been changed, use to move to the other digits.
  • Page 15 1. Plug the modem cable into the SERIAL port on the USB Port Adapter and modem. 2. Connect the USB Port Adapter to the Omniguard 4 USB port using the USB cable (included with your Omniguard 4). 3. Plug the phone cable into the modem and a working telephone line RJ11 phone jack.
  • Page 16: Appendix A: Troubleshooting

    (see Section 4: Turning Printer On/Off). After the paper jam is cleared, If you experience problems with your Omniguard 4, use this section use the PRINTER ON/OFF key to turn the printer back on. to try to resolve the problem. For additional information consult with...
  • Page 17: Appendix B: Specifications

    INLET 1 port and the INLET 2 (Reference) port. Accuracy: +/- .003” WC or +/-1% of reading whichever is greater In abatement applications the Omniguard 4 should be located outside the containment area and not in any antechambers (i.e. shower or Resolution: 0.001”...
  • Page 18: Appendix D: Limited Warranty

    To keep this warranty valid, the purchaser must (a) return signed a minimum negative pressure of -0.020”WC. Registration card to Engineering Solutions within fifteen (15) days Example #2: Room size is 20 x 50 with 12 ft ceiling. Requires of purchase, (b) have promptly informed Engineering Solutions’...
  • Page 19 Page 36 Omniguard™ 4 Owner’s Manual...