The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections
for installation and device replacement of several Banner family reading devices.
System cabling is made through spring clamp terminal blocks inside the TCNM-ACBB1 while the reading
device is connected to the TCNM-ACBB1through a 25 pin connector on the housing.
A 9-pin connector placed inside the TCNM-ACBB1 facilitates connection between an external PC and the
auxiliary serial interface of the reading device for configuration or data monitoring.
TCNM-ACBB1 can also house an accessory Backup and Restore Module to make system maintenance
extremely quick and easy.
Sep 2013
p/n 174477 Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Banner TCNM-ACBB1

  • Page 1 TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is made through spring clamp terminal blocks inside the TCNM-ACBB1 while the reading device is connected to the TCNM-ACBB1through a 25 pin connector on the housing.
  • Page 2: General View

    Each TCNM-ACBB1 supports only 1 single reading device + system accessories. Supposed Reading Device Models The TCNM-ACBB1 can be connected to the following readers using the 25-pin connector. • TCNM-AD •...
  • Page 3: Mechanical Installation

    TCNM-ACBB1 Installation Manual • TXHNM-SP Opening the TCNM-ACBB1 To install the TCNM-ACBB1 or during normal maintenance, it is necessary to open it by unscrewing the two cover screws. Disconnect the TCNM-ACBB1 from the power supply during this operation. Mechanical Installation TCNM-ACBB1 can be mounted to various wooden or plastic surfaces using the two self-threading screws (3.9 x 45 mm) and washers provided in the package.
  • Page 4: Power Supply

    After system functioning has been verified, close the TCNM-ACBB1 using the two cover screws. Power Supply Power is supplied to the TCNM-ACBB1 through the Vdc and GND pins provided on the spring clamp connector. The power switch switches the power supply ON or OFF for both the TCNM-ACBB1 and the connected reading device.
  • Page 5: System Wiring

    Connect the Network Cable Shield (Shield) to Filtered Earth through the jumper (default setting). System Wiring The connection and wiring procedure for TCNM-ACBB1 is described as follows: 1) Open the TCNM-ACBB1 by unscrewing the two cover screws. 2) Verify that the TCNM-ACBB1 power switch is off.
  • Page 6 Use flexible stranded wire and meet the following specifications. All positions: 24 - 16 AWG 0.2 - 1.5 mm² The TCNM-ACBB1 spring clamp connector pinouts are indicated in the pinout table. Refer to the reading device installation manual for signal details.
  • Page 7 25-pin connector. This is useful, for example, to pass power to connected accessories such as Encoder. See the relative reading device Reference Manual for details. To power TCNM-ACBB1 from the reading device, place the power source jumper in the "power from device" position as indicated.
  • Page 8 Chassis Grounding 9-Pin Reading Device Auxiliary Serial Interface Use the reading device auxiliary serial interface available on the internal TCNM-ACBB1 9-pin connector for configuration or data monitoring. Connect the device to a PC or Laptop using a straight through cable or a USB-RS232 converter. The connector pins are listed in the following table.
  • Page 9 The TCNM-ACBB1 Backup and Restore Module (separate accessory) provides configuration parameter backup. It can easily be installed by aligning it over its corresponding connector in the TCNM-ACBB1 and pushing down until correctly seated. When closed, the plastic support inside the TCNM-ACBB1 cover holds the module in place.
  • Page 10: Indicator Leds

    There are five Indicator LEDs that signal power and I/O activity and are visible from the outside cover. The Power LED is blue when power is correctly applied to the TCNM-ACBB1 and the power switch is turned on. This LED is red if power polarity is incorrect. In this case, the connected reading device and optional Backup Module are protected.
  • Page 11 TCNM-ACBB1 Installation Manual Environmental Features Operating Temperature Shock Resistance (EN 60068-2-27) 30 g; 11 ms 0 to 50 °C (+32 to 122 °F) Storage Temperature 3 shocks on each axis -20 to 70 °C (-4 to 158 °F) Protection Class (EN 60529) Humidity max.