TROUBLESHOOTING SUGGESTIONS

SYMPTOM
Power light not lit
Satellite does not fill
Satellite suffers excessive fill time Improper internal adjustments
Dispensed water not hot enough
Main tank does not heat
There are no user serviceable components in the appliance. In all cases of damage or component
malfunction, contact your Authorized Wells Service Agency for repairs.
POSSIBLE CAUSE
Circuit breaker off or tripped
Satellite not properly positioned
on shelf
Low water in main tank
Satellite not properly positioned
on shelf
Water temp thermostat not set
Dispense thermostat set too low
Tripped circuit breaker
Internal damage
14
SUGGESTED REMEDY
Reset circuit breaker
Set satellite in proper position
Verify water supply is fully on
Inlet solenoid strainer plugged -
clean strainer
Internal damage - contact
Authorized Wells Service Agency
Contact Authorized Wells Service
Agency
Set satellite in proper position -
verify connector securely seated
Contact Authorized Wells Service
Agency
Contact Authorized Wells Service
Agency