• The sensor must be firmly fastened in order not to vibrate.
• The sensor must not be placed directly behind a panel or any kind of material.
• The sensor must not have any object likely to move or vibrate in its sensing field.
• The sensor must not have any fluorescent lighting in its sensing field.
To access push buttons, you must open the sensor (see image, right):
a) Using a hex key, loosen the set screw located on the side of the housing.
b) Unscrew the housing cover.
1
MOUNTING
a) Bolt the bracket securely to the wall or other rigid surface.
Make sure that the two
b) Rotate the sensor to the appropriate angle for the application. When the bracket rotates, it will click. Every
click represents a 7
c) Lock the angle adjustment by tightening the two
Horizontal angle adjustments can be made by loosening the mounting bolts on the base and twisting to the
desired angle.
2
WIRING
Connect the wires to the door controller. Choose between NO and NC contact.
3
DETECTION FIELD DIMENSIONS
FALCON EX
Mounting height: 16 ft
Page 2 of 4
Page 2 of 4
INSTALLATION TIPS
- 18 Allen head bolts are loose so that the sensor can rotate freely.
5
16
'' angle adjustment.
1
2
Maximum angle
(+30° above horizon)
RED
12-24 VAC/VDC
BLACK
WHITE
COM
GREEN
NO
YELLOW
NC
FALCON EXXL
Mounting height: 8 ft
- 18 Allen head bolts.
5
16
Minimum angle
(-90° below horizon)
Set
screw
European wire color cross-reference:
US 
 EURO
red 
 green
black 
 brown
white 
 white
green 
 yellow
yellow 
 gray
FALCON EXWIDE
Mounting height: 11.5 ft
75.5355.04 FALCON EX 20190822