Ebyte E78-868LN22S User Manual page 22

Lorawan wireless module
Hide thumbs Also See for E78-868LN22S:
Table of Contents

Advertisement

E78-868LN22S
Command
character
CNBTRIALS
(Set the number
of times to send)
Command
character
CRM
(Set reporting
mode)
OK
Precautions
Command
Command Format
Type
Test
AT+CNBTRIALS=?
command
Query
AT+CNBTRIALS?
command
AT+CNBTRIALS=<MType>,
Setting
<value>
command
Parameter
Description
<MType>:0:unconfirm 包, 1:confirm 包。
<value>:the maximum number of times to send, value range: 1~15;
Return value
description
AT+CNBTRIALS=1,2
Example
OK
Precautions
Need to set before sending data
Command
Command Format
Type
Test
AT+CRM=?
command
Query
AT+CRM?
command
AT+CTXP=<reportMode>,[re
Setting
portInterval]
command
Parameter
<reportMode>:
Description
0- acyclic reporting data;
1- Periodic reporting of data;
<reportInterval>: This parameter is only available when data is reported
periodically. Time interval of periodic report data, unit: s.For different Dr's,
the minimum period allowed is different. The definition of period level is
adopted, as shown in the following table.
Rate\cycle(s)\level
Return value
DR0
description
DR1
DR2
DR3
DR4
DR5
response
+CNBTRIALS: "MType","value"
OK
+CNBTRIALS:<MType>,<value>
OK
OK
response
+CRM:"reportMode","reportInterval"
OK
+CTXP:<reportMode>,[reportInterval]
OK
OK
LV1
LV2
150
300
75
150
35
70
15
30
10
20
5
10
22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents