Ebyte E78-868LN22S User Manual page 17

Lorawan wireless module
Hide thumbs Also See for E78-868LN22S:
Table of Contents

Advertisement

E78-868LN22S
( Query the
current status of
the device )
Command
character
CJOIN
(Set Join)
command
Query
AT+CSTATUS?
command
Setting
<status>:
command
00 – No data operation
01 – Data transmission
02 – Data transmission failed
03 – Data sent successfully
04 – JOIN succeeded (only in the first JOIN process)
Parameter
05 – JOIN failed (only in the first JOIN process)
Description
06 – The network may be abnormal (Link Check result)
07 – Successful data transmission, no
08 – Send data successfully, with
AT+CSTATUS?
Return value
+CSTATUS=03
description
OK
Example
Query the current status of the device
Command
Command Format
Type
Test
AT+CJOIN=?
command
Query
AT+CJOIN?
command
AT+CJOIN=<ParaValue1>,
Setting
[ParaValue2],....
command
[ParaValue4]
Parameter
<ParaTag1>, [ParaTag2], ......[ParaTag4]: Authentication parameter tag:
Description
1, 2,......4 ;
[ParaValue1], [ParaValue2], ......[ParaValue4]: Authentication parameter
value: 1, 2,......4;
<ParaTag1>, indicates that the JOIN operation is performed, ,ParaTag1
Ranges:
Return value
0– stop JOIN
description
1– start JOIN,Restart the JOIN process again. For modules that enable hot
start, performing this action clears the saved JOIN context parameters.
[ParaTag2] Indicates whether the automatic JOIN function is enabled.The
factory value is 1, ParaTag2 value range:
OK
+CSTATUS:<status>
OK
downstream
downstream
response
+CJOIN:<ParaTag1>,[ParaTag2],...[Para
Tag4
]
OK
+CJOIN:<ParaValue1>,[ParaValue2],...[
Para
Value4]
OK
If the input is legal, first return OK, then
start automatic authentication and return
the authentication result.
+CJOIN:OK Authentication succeeded
+CJOIN: FAIL authentication failed