  • Page 1 OWNER'S MANUAL Cross Ventilation Cartridge Dust Collector l MCB SerieS...
  • Page 2 For quick future reference, fill in the system and filter information in the spaces below. Should you need assistance, call the customer service number shown below. To expedite your service, have the following information available when contacting UAS. UAS ORDER #: _________________________________________________________ UNIT MODEL #: ________________________________________________________...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page IMPORTANT NOTICE ..................1 INTRODUCTION ....................1 2.1 Unit Nomenclature..................1 2.2 Description and Operation .................1 2.3 Air Filtering Operation ................1 2.4 Filter Cleaning Cycle ..................1 SPECIFICATION TABLE ..................4 INSTALLATION ....................4 4.1 Off Loading and Inspection ................4 4.2 Installation Planning ...................4 4.3 Module Installation ..................4 4.3.1 Compressed Air Connection ..............4 4.4 Motor/Blower Installation ................6...
  • Page 4 SAFETY PRECAUTIONS We have provided many important safety messages in this manual and on the MCB unit. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”.
  • Page 5: Important Notice

    The quick blast of compressed air Thank you for selecting UAS dust collection equipment induces additional air from the clean air plenum which to assist you in your commitment to a clean and safe combine to produce a shock wave, dislodging the dust environment.
  • Page 6 Revised 03/15 Crossflow Dust Collector...
  • Page 7 Revised 03/15 Crossflow Dust Collector...
  • Page 8: Specification Table

    40,500 16,320 36x7.5x8 need to be spaced with a 1" gap between side panels. A UAS supplied trim strip will bridge the gap between the units. 4. INSTALLATION 3. To install the trim strip, remove all fasteners on the front panel of the adjoining corner from 4.1 OFF LOADING AND INSPECTION...
  • Page 9 Revised 03/15 Crossflow Dust Collector...
  • Page 10: Motor/Blower Installation

    Figure 3 for compressed air piping connection. horizontal channel. Place roof panels in position, one 5. UAS recommends 1" diameter air line to supply the at a time, and lock together in same method as side unit. A flexible pipe grommet is provided to seal the panels.
  • Page 11 Revised 03/15 Crossflow Dust Collector...
  • Page 12 Revised 03/15 Crossflow Dust Collector...
  • Page 13 Revised 03/15 Crossflow Dust Collector...
  • Page 14: Electrical Installation

    • VFD with DPC for on-demand pulse cleaning. to the pulse control panel. Refer to Figure 8 when Refer to UAS sales order to verify the number of motor making connections from the pulse control panel to the branch circuits (number of modules) and the pulse solenoid valve enclosure(s).
  • Page 15 Revised 03/15 Crossflow Dust Collector...
  • Page 16: Operating Adjustments

    Continue adjustments, when required, until the The compressed air pressure should be between high setpoint reaches 5". No further adjustments should 90-110 PSIG (6.2-7.6 BAR). UAS’ pulse control be made above 5" w.g. panels are factory set to pulse every 10 seconds.
  • Page 17 Revised 03/15 Crossflow Dust Collector...
  • Page 18: Dust Drawer Removal

    (pivoting counter-clockwise) into a horizontal position. consistently above 5" w.g. (127 mmAq) or system Next, lift the right handle (pivoting clockwise) taking airflow is inadequate. To order filters contact UAS care that the retaining clip (on the backside of the at 888-515-8800.
  • Page 19: Troubleshooting Guide

    Revised 03/15 Crossflow Dust Collector 8. TROUBLESHOOTING GUIDE Use the troubleshooting guide to correct any problems that occur with your dust collection unit. If the problem or condition continues, contact UAS customer service at 1-800-252-4647. PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTIONS Blower motor won’t start or will...
  • Page 20: Illustrated Parts - 6 And 9 Foot Wide Modules

    Revised 03/15 Crossflow Dust Collector 9. ILLUSTRATED PARTS 6 and 9 Foot Wide Module...
  • Page 21: Mcb Parts List - 6 And 9 Foot Wide Modules

    SCREW, HEX WASHER, 5/16-18 x 3/4 LG, SWAGEFORM 32-10032-XXXX BLOWER WHEEL, (SIZE SPECIFIC TO UNIT) 32-10029-XXXX BLOWER INLET CONE (CONSULT UAS) 33-10092-XX CARTRIDGE FILTER (VIEW LABEL ON END OF FILTER AND CONSULT UAS) 38-0780 1/4" NYLON TUBING 38-0781 FITTING, BULKHEAD, UNION, 1/4" TUBING 38-0814 TUBE FITTING, 90 DEG ELBOW, I/8"...
  • Page 22: Illustrated Parts - 3 Foot Wide Modules

    Revised 03/15 Crossflow Dust Collector 11. ILLUSTRATED PARTS 3 Foot Wide Module...
  • Page 23: Mcb Parts List - 3 Foot Wide Modules

    SCREW, HEX WASHER, 5/16-18 x 3/4 LG, SWAGEFORM 32-10032-31ST BLOWER WHEEL 32-10029-0003 BLOWER INLET CONE 33-10092-XX CARTRIDGE FILTER (VIEW LABEL ON END OF FILTER AND CONSULT UAS) 38-0814 TUBE FITTING, 90 DEG ELBOW, I/8" NPT MALE x 1/4" TUBE 38-0829 PLUG-PIPE, 1" NPT, BLACK IRON 39-10013-0001...
  • Page 24: Warranty

    UAS is limited to furnishing replacement parts F.O.B. UAS’ factory or making repairs at UAS’ factory of any parts that are determined, upon inspection by UAS, to be defective. In no event will UAS be responsible for labor or transportation charges for the removal, reshipment or reinstallation of the parts.