TDI T URBO WIN TECH DEVELOPMENT FROM TABLE OF CONTENTS SECTION SUBJECT PAGE General Information ................1 Description ..................... 1 Product Identification ................1 Physical Characteristics ................. 2 Performance ..................2 Orientation of the Starter ............... 2 Installing the Starter ................2 Supply Line Installation ................
Therefore, if a vane type starter motor is The housing proof pressure is 600 psig and is also being replaced, TDI recommends that all lubrication shown on the nameplate. This means that the turbine devices and lines be removed to minimize flow housing will not burst when subjected to a static restrictions.
This type of valve actuates from a fully WARNING closed to a fully open position very rapidly. TDI offers a Be sure to either bleed the pressurized air reservoir variety of relay valves such as P/N RLVA-25683-001-2- and/or safety the system such as closing all valves 01, which is a 1-1/2"...
If the overhung section of the starter is not otherwise WARNING supported, TDI recommends that the exhaust piping be Do not connect the turbine housing vent line to the supported with a suitable bracket(s).
mist injection type WARNING lubricators/devices in supply line to a TDI air starter. These special conditions must be followed for the Where starter to conform to the ATEX Directive and for the used...
CAUTION Consult your TDI distributor if you have exhaust Do not engage the starter while the engine is plumbing that creates back pressure and reduces starter running.
This warranty constitutes the entire obligation of Tech Development relating to the sale and use of such product, and TDI's maximum liability is limited to the purchase price of such product at the date of purchase. In no event shall TDI be liable for incidental, indirect, consequential, or special damages of any nature arising from the sale or use of such engine starter product.
TDI TURBOTWIN TECH DEVELOPMENT FROM 6.0 OPERATOR’S TROUBLESHOOTING GUIDE TROUBLE PROBABLE CAUSE SOLUTION 1. Air always flow through A. Relay valve improperly A. Check typical installation exhaust installed. diagram and correct. B. Relay valve not sealing B. Check for damaged sealing properly.
TDI TURBOTWIN TECH DEVELOPMENT FROM Figure 5. T100-VE T Air Starter Installation Drawing (Multiple Starters) URBO Page 12 Publication T1-932 Issued May 20, 2016...