Changing Lock Timer Setting
The lock timer can be changed in this mode.
1. Turn key switch (1) to ON position.
2. Unlock the numeric keypad.
3. Push Key F (2) and Key 2 (7) simultaneously for more
than 2 seconds.
4. Two indicators (4) and (5) blink simultaneously, and the
buzzer sounds.
5. Push a relevant key to set the lock delay timer.
List of lock time assigned to each key
as timer
Key 1:
15 seconds (Factory default)
Key 2:
3 minutes
Key 3:
5 minutes
Key 4:
10 minutes
Key 5:
15 minutes
Key 6:
30 minutes
Key 7:
60 minutes
Key 8:
90 minutes
Key 9:
120 minutes
Key 0:
0 seconds
6. Push Key F (2) for more than 2 seconds. The buzzer
sounds three times and the change is registered.
This is the end of the procedure.
f
NOTE: If you want to terminate the process, push key C (6) or
turn key switch (1) OFF.