Garland ED Series Installation & Operation Manual

Electric counter units

Advertisement

INSTALLATION & OPERATION MANUAL
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL RANGES LTD.
1177 Kamato Road
Mississauga, Ontario ,Canada L4W 1X4
Phone: 905-624-0260
Fax: 905-624-5669
Part # 4521653 Rev 1 (03/05/13)
Part # 4521653 Rev 1 (03/05/13)
GARLAND ED SERIES
ELECTRIC COUNTER UNITS
APPLIANCE
WARNING:
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
General Inquires 1-95-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-4526
Canada or USA Parts/Service 1-800-427-6668
© 2005 Garland Commercial Industries, LLC
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garland ED Series

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the state of california to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT INFORMATION . . . . . . . . . . . . . 2 Griddles – Models: ED-15G, ED-24G & ED-36G DIMENSIONS AND SPECIFICATIONS . . . . . 4 Grooved Griddles –...
  • Page 4: Dimensions And Specifications

    DIMENSIONS AND SPECIFICATIONS LOADING AND VOLTAGE CHART Total KW Loading North America Export MODEL NUMBER 208V 240V 220V/380V 240V/415V ED-15H ED-15HSE ED-15THSE Contact Factory ED-15F 5.93 ED-15SF ED-30FT 10.6 10.6 11.86 10.3 ED-30SFT 16.0 16.0 16.0 16.0 ED-15G ED-24G ED-36G 10.1 10.1 10.1...
  • Page 5: General Installation

    GENERAL INSTALLATION Unpacking 5. To secure the front, open the lower front panel, place banking plate over the two holes (one on each unit) and Carefully remove units from cartons. Remove all packing secure banking plate using sheet metal screws supplied. materials from units.
  • Page 6: Installation Of Counter Stands (Optional)

    Inserts 8-32 machine screws screws. through the 7/32” (5mm) diameter holes in stand into the nutserts in the bottom of ED series unit. 5. Smooth the silicone seal into the crevice with finger or tool to provide a cove seal.
  • Page 7: Individual Model Installations

    INDIVIDUAL MODEL INSTALLATIONS Hot Plate – Model ED-15H Electrical Connection Wall Clearances A knockout is provided near the front left side of the unit located behind the control panel. To view knockout, loosen Do not install appliance closer to a wall of combustible the two acorn nuts and hinge control panel downward.
  • Page 8: Operating The Sealed Hot Plate

    INDIVIDUAL MODEL INSTALLATIONS continued Supply Connection Operating practices are very important for the efficient use of these elements: For supply connection, use wire suitable for 75°C (167°F). 1. Pot bottoms must be flat. This increases heat transfer to Electrical Connection the pot.
  • Page 9: Controls

    Calibration Instructions Controls 1. Field calibration is seldom necessary and should not 1. All ED series fryers are equipped with a manually be attempted unless experience with cooking results resettable high limit located at the rear of the element definitely proves that the control is not maintaining the termination box.
  • Page 10: Broilers - Models: Ed-15B

    Operating Instructions Controls ED series food warmers are supplied with a removable tank Infinite switches are used to control the elements. assembly. Fill tank with 1-1/4” (32mm) to 1-1/2” (38,mm) of HI to 5 High heat water.
  • Page 11: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Cleaning Exterior Finishes 3. Clean the top of the unit with a cloth soaked in a mild detergent and hot water, including the front of the Black Baked Enamel – Allow equipment to cool after use element assembly housing. Rinse with a clean cloth and wash all grease deposits from exterior with a hot mild dipped in clean hot water, Dry thoroughly with a clean detergent or soap solution.
  • Page 12: Broiler Interior And Under Broiler Grates

    CLEANING AND MAINTENANCE continued Broiler Interior and Under Broiler Grates Periodic Cleaning Debris and grease that gathers inside the broiler and must be Over time debris carbonizes on the broiler grates requiring removed. major cleaning with detergent soap or degrease agent. The broiler racks can be completely removed from the attached Daily elements for cleaning.
  • Page 13 Part # 4521653 Rev 1 (03/05/13) Page 13...
  • Page 14 Page 14 Part # 4521653 Rev 1 (03/05/13)
  • Page 15 Part # 4521653 Rev 1 (03/05/13) Page 15...

Table of Contents