Page 2
Setting the rotary switch 4.10. Symbols used 1.3. Case reassembly 4.11. Warnings 1.4. Configuration via Up! (service app) 4.12. easyWallbox SAFETY FIRST START Intended purpose of 2.1. easyWallbox Turning on 5.1. easyWallbox Use not in accordance with the intended purpose 2.2.
About installation in Mode 2 with Power Upgrade ABOUT THE INSTALLER MANUAL Following this procedure, easyWallbox can be correctly installed in Mode 2 Thank you for choosing easyWallbox. Please spend some minutes and be used up to 32 A, (7.4 kW) in compliance with IEC 61851-1:2017.
Page 4
1.4. Warnings Danger of electric shock and fire Before using easyWallbox, read the contents of this manual carefully to Children or other persons not able to evaluate risks related to the ⚫ ⚫ acquire familiarity with the instructions for use and the safety indications.
Page 5
The installation should comply with local installation regulations. current and nominal voltage for Mode 2 respectively 32 A and 250 V in single-phase. Hence easyWallbox power can be increased up to 7.4 kW (32 A) in compliance with Mode 2 current and voltage limits, by using an...
Page 6
⚫ understand all related risks. ENGIE Eps does not assume any liability avoid use not in accordance with the intended purpose ⚫ for damage to persons or things that may arise from failure to respect avoid incorrect use of the device ⚫...
The design of the device is the result of in-depth study intended to provide an ergonomic, lean and intelligent work tool. 102 mm front view side view Size of easyWallbox charging station with connector in place 325 mm Product description Type 2 connector port Case...
Page 8
Installation of in Mode 3 easyWallbox 3.2. Identification label (see Installer Manual, not for France) The identification label is on the backside of the charging station. The information on the label is shown in the Figure below. The data shown may differ from that in the Figure, depending on the version of the product.
Page 9
- We recommend contacting qualified personnel or service for any Android version compatibility** Lollipop (5.0) or higher IOS version compatibility** 12 or higher questions or doubts concerning easyWallbox’s use, installation, Communication Protocol Proprietary and maintenance. Dynamic Power Management Y, by installing the included sensor...
⚫ standards. measures and rescue methods in the installation site - ENGIE Eps does not assume any liability for damage caused by non-compliant use or unauthorised modifications to the device. must not be installed in places: easyWallbox at risk of explosion (EX environment) ⚫...
Page 11
Danger of fire and explosion easyWallbox must be installed in areas where there are no Do not stack loads on the box containing easyWallbox and pay incendiary or explosive substances, such as close to petrol attention to the signs and specific instructions on the package.
Page 12
Correct positioning of the charging station is important for its operation. been prepared for the installation and it must be transported manually When the installation wall is chosen for easyWallbox, take the distances to the wall chosen for its installation.
Page 13
Wall-mounting height for easyWallbox. Use a drill to make the holes Put the fixing plugs into the in the wall. holes using a hammer. Follow the steps below. Remove the aesthetic cover of easyWallbox set up by mechanical interference in the CASE, using the groove on the bottom.
Page 14
Store the power cable with the others easyWallbox accessories for use again in Mode 2 The power cable should be stored where it cannot cause danger to anybody (e.g. risk of tripping) and where it cannot be damaged while stored. Remove the front panel of easyWallbox.
Page 15
Both wall-mounting and switchboard-mounting versions of the socket are acceptable. If not present, proceed with the installation of the socket in proximity of easyWallbox. For the installation, please refer to the plug specific instructions. Once installed, please proceed to next instruction.
Page 16
Connect the cables to the J1 tool-free ‘push-lock’ terminals (4). ⚫ ENGIE Eps does not assume any liability for damage caused by Connect Line (L) and Neutral (N) as indicated on the board. non-compliant installation of the device. Installers are We recommend using flexible cables with the following max.
Page 17
4.10. E = 26.5 mm F = 6.1 mm easyWallbox can work without Dynamic Power Management. To connect the current sensor: In this case, the installation of a dedicated sensor is not necessary but avoidance of blackouts is not guaranteed.
Page 18
POSITION 1: DPM is always turned off ⚫ - Before connecting to a power supply, make sure that easyWallbox POSITION 2: DPM can be enabled or disabled via the ⚫...
Page 19
The installation and parameter set-up should be in accordance contract. with local applicable standards. Please check local updates of standards before setting up parameters. If the instructions in this paragraph are not followed, all parameters remain as initially set for Mode 2. This reduces easyWallbox’s performance.
- If the instructions in paragraph 4.12 are not followed, all parameters call qualified personnel promptly so that the device can be repaired ⚫ remain as initially set for Mode 2. This reduces easyWallbox’s or, if irreparably damaged, taken out of service performance.
Once installation is completed, recharging an electric vehicle with There is a strip of LEDs on the front of the charging station which is very easy. All you have to do is: combines visual signals and alarms indicating the status of easyWallbox easyWallbox: Ensure that easyWallbox is connected to an active power supply Check if the LED status indicator is BLUE.
Using My app. ⚫ easyWallbox Once the process is stopped, refer to the next chapter. Please note that, once the charging process is stopped, the connector must be extracted from the vehicle before the charging process can be restarted.
Any defects must be rectified immediately by the cable tidily, if necessary by rolling it around the case of qualified personnel. easyWallbox. Anyhow, the cable must be placed in a safe manner, where it does not obstruct anyone and cannot be damaged (e.g. pressed by vehicles) control of operational readiness ⚫...
9.1. Power upgrade Risk of electric shock. Before starting dismantling, be sure that the easyWallbox is not connected to any power supply. Any operation of installation, maintenance and dismantling should only be done when the power supply is switched off on your service panel and the industrial connector in Modo 2 is removed.
Page 25
Also remove the sensor cable (if it exists) Reposition the aesthetic cover on the device. Disconnect the twisted cable to the J7 ‘push-in’ spring ⚫ terminals (6). ⚫ Remove the twisted cable from the cable gland (B). Unscrew the three screws in the wall.
Page 26
⚫ - the temperature of the place where the device is stored must be If you have any questions about the installation of easyWallbox, contact between -25°C and +40°C the authorised assistance centre. Various assistance centres available to - the average temperature over 24 hrs must not exceed 35°C...
Page 27
The Italian version of this manual is the original. Instructions in other languages are translations of the original manual. ENGIE Eps will not be held responsible for any damage that may directly or indirectly result to people, things or animals due to the failure to comply with all the prescriptions indicated in this Manual and the warnings regarding the installation, use and maintenance of the easyWallbox.
Need help?
Do you have a question about the easyWallbox and is the answer not in the manual?
Questions and answers