Dometic OPTIMUS EPS Series Installation And User Manual page 53

Electronic power steering with electric actuator
Table of Contents

Advertisement

L w , m (ft)
AWG (mm
< 1.0 (3.3)
6.0 (13.5)
< 3.0 (9.8)
4.0 (21.0)
< 4.5 (14.7)
2.0 (34.0)
Table 5-5
BREAKER
7"
+
12V BATTERY
Figure 5-13.
EN
NOTE: Typical Source Connections
• Direct to the batteries.
• To battery switches. (Never switch the negative wire.)
• To a bus bar or power distribution panel. Ensure the wire size from the
bus to the batteries is sufficient to handle the peak current of all devices
connected to the bus.
• A 60A circuit breaker, designed for marine use.
• Red wire that meets ABYC requirements, of the appropriate size for the
intervening wire length between the actuator harness and the battery
(see figure 5-13 and table 5-5).
• Crimp lugs sized for connecting the circuit breaker to the power source.
• Secondary circuit protection devices if required (see note).
NOTE: Circuit Protection
• ABYC standards require a circuit protection device within 7" (180mm)
of the power source on all wires carrying positive voltage.
• If the circuit breaker is more than 7" (180mm) from the source, a
secondary device (circuit breaker or fuse) must be located within 7"
)
2
of the battery to protect the intervening wire.
• Secondary device must be rated based on intervening wire size, and
usually has a higher rating than the circuit breaker.
• Refer to ABYC E-11 – AC and DC Electrical Systems on Boats for
more details.
ELECTRIC ACTUATOR
BREAKER
BATTERY
SWITCH
7"
TOTAL
INTERVENING
WIRE LENGTH
BUS BAR
L w
+
12V BATTERY
ELECTRIC ACTUATOR
12V
24V
5-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optimus eps ea1000Optimus eps ea1100Optimus 360

Table of Contents