6. OPERATION
6.2.1.
Check that the release valve on the hydraulic unit is fully closed, ready for operation (fig.2).
6.2.2.
locate the flat pressing plate/V-blocks on to the working table, push down the locating pins to ensure the plates don't slip. Place
workpiece on to the plates and position the head of the hydraulic unit over the centre of the workpiece.
Note:
Care must be taken to ensure the plates don't fall from the working table.
WARNING! DO NOT apply off-centre loads.
6.2.3.
Rotate the speed control valve clockwise to the 'Quick Without load' position (fig.2) to bring the ram head rapidly into contact with
the workpiece. once the ram head has made contact with the workpiece, rotate the speed control valve anti-clockwise to the 'Slow
With load' position (fig.2) for more controlled pressing with full load capacity.
Note:
The 'Quick Without load' setting will only operate to approximately 2tonne of load. Monitor the pressure gauge during operation to
ensure that the rated capacity of the press is not exceeded.
6.2.4.
When work is complete turn the release valve anti-clockwise (fig.2) to release the pressure. The piston and the ram head will retract
automatically.
Note:
Always keep the ram head retracted after use.
7. MAINTENANCE
Note:
Maintenance and repair must only be carried out by qualified person. Contact your Sealey stockist for details.
7.1.
Always keep the press clean, dry and lubricate all moving parts at regular intervals.
7.2.
When not in use always store in a dry location with the ram head retracted.
7.3.
Should you need to check or replace oil ensure the ram head is fully retracted. Remove the oil reservoir filler plug and top up using
Sealey hydraulic jack oil (Sealey ref: HJo500MlS or HJo5lS). DO NOT use brake fluid. After filling purge the system to remove any
air.
ENvIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey limited