500-50 & 500-50A Irrigation Console User's Guide •••••••••••••••••••••• Includes setup, safety, repair, and warranty information for the Stryker Total Performance System. For answers to questions about other equipment, see the information supplied with that equipment. V e r s i o n US Patents D398,598;...
Any license granted by Stryker Corporation to use the software contained in its; products does not give the licensee the right to copy, alter, disassemble, reverse engineer, create derivative works of such software or to use such software in either original or modified form in any product other than the Stryker Corporation product in which the software was initially installed by Stryker Corporation.
Where to Find Answers When you have questions about your Stryker TPS products, there are several places to find the answers. In this book Use this book to set up your system and select console options. This book also contains information on system safety, repair, and component warranty.
▪ DO NOT modify any bur to fit the handpieces. Use only Stryker approved burs. Other burs may not fit properly in the handpiece. During use they may come out of the handpiece or bend which would result in damage to tissue in the surgical site due to loss of control of the bur.
System Overview The Stryker Total Performance System is intended for use in the cutting, drilling, decorticating, and smoothing of bone and other bone related tissue in a variety of surgical procedures. It is also used for the placement or cutting of screws, wires, pins, and other fixation devices as it can be used to cut metal.
Stryker Endoscopy handpieces. Pay close attention to the User/Patient Safety Information. ▪ Familiarization with the Total Performance System prior to use is important. If you have any questions, contact your Stryker Instruments representative or Stryker Customer Service at 1-800-253-3210.
The Control Screen TPS Start-Up Screen This display appears on the screen every time the console is turned on. This display remains on the screen until a cord is plugged into one of the TPS handpiece ports or the OPT button is depressed. If a handpiece cord is plugged into a handpiece port when the console is turned on, this display shows momentarily before changing to either a no handpiece...
Functions of the Control Screen The TPS console allows the user to select functions and settings such as handpiece selection, speed, and direction. Designed to be easy to use and understand, the touch sensitive control screen allows you to set the system controls with the touch of a finger. Interactive icons on the control panel represent system components and functions.
Select Your System Settings Standard Features NOTE: When the console is turned on, its default setting is factory default unless a Surgeon Preference setting is Main Option Icon selected as the start up default. See Surgeon Preference for further details. The option icon appears on all handpiece screens .
Quick Reference Guide Icon Definition Handpiece Select Footswitch Icon: Appears when This type of icon appears when High: Enables handpiece to oper- a footswitch is connected to the a cord (without a handpiece) is ate in a high speed mode. console.
Saw Handpiece Screen TPS Oscillating and Sagittal Saws POWER/WATER ADJUSTMENT The power icon functions as a toggle switch for power and water settings. Power and irrigation adjustments are made using the adjustment arrows. As the power setting is reduced from 100%, a vertical bar displays to correspond to the lower selected maximum power.
Rotary Handpiece Screen SPEED/WATER ADJUSTMENT The speed icon functions as a toggle switch for speed and water settings. Speed and irrigation adjustments are made using the adjustment arrows. DIRECTION OPTIONS FORWARD Clockwise REVERSE Counterclockwise This screen appears when a TPS rotary handpiece is selected. The TPS Universal Drill is plugged into the TPS2 port and the speed is set at 75,000 RPM.
Page 14
TPS1, TPS2 and the footswitch icons indicate that other instruments are plugged into the console. Operation in low speed mode. The Stryker Leibinger Hummer4 REF 5290-601-100 and Stryker Endoscopy Formula REF 375-701-500 provide cutter recognition capabilities. When a cutting accessory with cutter recognition...
Main Option Screen Select the OPT icon to access the MAIN OPTION screen. This screen allows direct access to the handpieces attached to the console, console and user settings, and system information. OPTION 1, 2, and E icons appear only when handpieces are plugged into the corresponding console ports.
System Information Screen Selecting the INFO icon from the MAIN OPTION menu displays the part numbers and revision levels of the configured system components. This information is used as a diagnostic aid only. Return to the MAIN OPTION screen.
Handpiece Adjustment Screen Select a Handpiece Option icon from the MAIN OPTION ATTACHMENT: Use the arrow icon on the left to scroll screen to access this screen. through the list of attachments. Select the attachment that is assembled to the handpiece by stopping on it. NOTE: For quick access to this screen, touch the handpiece title displayed at the top of any handpiece screen.
Console Adjustment Screen Select the CONSOLE ADJUSTMENTS icon from the MAIN OPTION screen to access this screen. Select CONTRAST, BRIGHTNESS or VOLUME then press the arrow icons to change the setting. Contrast: Screen contrast lightens at higher settings. The chosen setting remains until reset.
Footswitch Adjustment Screen This screen appears only when using a TPS Footswitch that is Revision 3 or newer. See Standard Features. NOTE: The Footswitch revision is displayed on the SYSTEM INFORMATION screen. Access this screen by selecting the Footswitch icon on the HANDPIECE CONTROL SCREEN or HANDPIECE ADJUSTMENTS screen.
Footswitch Button Mapping Screen Access this screen by selecting the ADVANCED icon on the FOOTSWITCH ADJUSTMENTS screen. The default functions of each footswitch pedal and button can be reprogrammed to accommodate the surgeon's preferences. Depending on the type of handpiece displayed at the top of the screen, one or more of the following options will be available on this screen.
Handpiece Button Mapping Screen Access this screen from the Handpiece Adjustment screen. Use it to change handpiece button functions. Depending on the features of the handpiece, as many as five buttons can be reprogrammed. Identify corresponding button numbers by pressing the buttons on the handpiece. When the handpiece button is selected, the corresponding function is displayed on the screen.
• Settings saved by a previous surgeon • Collection and storage of new settings Using factory settings 1. Use the arrows to obtain "Stryker" and "Factory Default." NOTE: The EDIT, DELETE and padlock icons do not function while factory default settings are selected.
Contact your Stryker service representative. Error 02 Cutting accessory requires additional console hardware. See the instructions supplied with the cutting accessory. The Total Performance System is not field repairable. In case of operating difficulties, Stryker products must be returned for maintenance or repair.
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note that FCC regulations provide that changes or modifications not expressly approved by Stryker Instruments could void your authority to operate this equipment.
Place and date of issue (of this Doc): Kalamazoo, Michigan USA, January 2004 Signed by or for the manufacturer: Name (printed): Paul Freestone Title: Director, Regulatory Affairs, Quality Assurance Hereby, Stryker Instruments, declares that this Short Range Device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Guidance and manufacturer's declaration - electromagnetic emissions The TPS Console is intended for use in the electromagnetic environment specified below. The customer or the user of the TPS Console should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions...
Page 27
Guidance and manufacturer's declaration - electromagnetic immunity The TPS Console is intended for use in the electromagnetic environment specified below. The customer or the user of the TPS Console should assure that it is used in such an environment. Compliance level Immunity test Electromagnetic environment - guidance IEC 6060...
Page 28
Guidance and manufacturer's declaration - electromagnetic immunity The TPS Console is intended for use in the electromagnetic environment specified below. The customer or the user of the TPS Console should assure that it is used in such an environment. Immunity test Compliance level IEC 6060 Electromagnetic environment - guidance...
For all TPS products unless otherwise specified. In the U.S.A. only, products of Stryker Instruments are warranted to the original purchaser for a period of one year from the date of purchase, with exceptions noted below. Products are warranted to be free from defects in material and workmanship. Abnormal wear and tear or damage caused by misuse or by failure to perform normal and routine maintenance as set out in the Maintenance Manual or Operating Instructions, or as demonstrated by an authorized Stryker Instruments representative, is not covered by the warranty.
Page 32
4100 E. Milham Kalamazoo, Michigan (USA) 49001 European Authorized Rep: 1-800-253-321 RA/QA Manager 1-269-323-7700 Stryker France ZAC Satolas Green Pusignan Av. de Satolas Green 69881 MEYZIEU Cedex France...