Description of the running cycle
If the bath is connected with mains power supply, the controller's signal lamp (T) is on. Pressing any button starts the illu-
minated display (V). The display shows alternately the time and the temperature and the line of pictogrammes indicates the
readiness of the functions.
When connected to power supply the indicated time is 00:00 until it has been adjusted. (See also the "Time adjustment"
section).
If the bath is empty, the display (V) shows air temperature.
If the bath is fi lled with water, the display (V) of the control panel will be activated automatically (unless the display has been
not activated previously manually) at the moment the lighting (halogen) and sidemassage functions are ready for use. The
line of pictogrammes displays pictogrammes and shows the readiness of function(s).
When emptying the bath from water, the pictogramme (S6, S8, S10), indicating the readiness of additional massage and then
simultaneously pictogrammes of sidemassage and lighting (halogen) will turn off in the line of pictogrammes on the display
(V).
The display (V) of the control panel shows the pictogrammes of airmassage
and underwater massage, indicating to their readiness of use, independent of the water level.
The automatic dry-blowing of the airmassage jets starts 20 minutes after the sidemassage and the disappearance of light-
ing (halogen) pictogramme in the pictogramme line or 10 minutes after switching off the airmassage function (if air massage
function was used after switching off the above mentioned pictogrammes), During the automatic dry-blowing of the airmas-
sage jets the signal lamp (G) and the pictogramme of the dry-blowing fl ash at the same time. If the airmassage button (B) is
pressed during the dry-blowing, the function stops.
30 minutes after the last pressing of the button or20 minutes after the sidemassage and the disappearance of lighting (halo-
gen) pictogramme from the pictogramme line, the display (V) enters the stand-by regime, i.e. only the signal lamp of the
power supply (T9) is lit up.
The automatic dry-blowing of the airmassage jets
The automatic dry-blowing of the airmassage jets starts 20 minutes after the pictogrammes of the sidemassage and lighting
(halogen) disappear in the pictogramme line or 10 minutes after switching off the airmassage function (if air massage function
was used after switching off the two above mentioned pictogrammes), The dry-blowing operates at maximum speed for 20
seconds and then switches off gradually.
Automatic dry-blowing of airmassage jets can be blocked/activated by pressing simultaneously buttons + (H) and - (F) for 2,5
seconds during the non-active time of the function. The turning on of the sign lamp (G) and the fl ashing of the airmassage
pictogramme (duration 7 seconds) indicate the activation regime.
The sign lamp (G) (duration 7 seconds) of the airmassage button and the disappearance of the airmassage pictogramme
from the line of pictogrammes for 7 seconds indicate the activation of the blocking regime.
The automatic dry-blowing is in operation if the signal lamp of the airmassage switch (G) and the pictorgramme of airmas-
sage on display (V) start fl ashing at the same moment the pictogrammes of sidemassage and lighting (halogen) disappear.
Flashing continues until the end of the dry-blowing function.
NB! Automatic dry-blowing of airmassage jets is possible only if the water level has allowed to display the picto-
grammes of the side massage and lighting (halogen) function on the display for at least 1 minute.
Time adjustment
By pressing lighting button (A) simultaneously with button (E) for 2,5 seconds the time display starts to fl ash. By pressing
the light button (A), hour-digit can be changed and by pressing the side massage button (E), minute-digit can be changed. If
these buttons are not pressed during 2,5 seconds the reading is recorded.
NB! The time has to be always adjusted after:
- After connecting the product to the power supply,
- Power failure
Reading 00:00 indicates the need for the adjustment of the time.
Turning the display
The display can be reversed by pressing lightly the button of lighting (A) and the button of side massage (E).
NB! All functions stop and the display (V) goes to stand-by regime (only the supply signal lamp (T) is on 30 minutes
after the last pressing of the button.

5.3 FUNCTIONS

Underwater chromotheraphy lighting
The function consists of up to four synchronized LED-lamps. The function has a manual and an automatic working regime.
Colours can be changed with repeated pressing of button (A) (the sequence of pressings is until 2,5 seconds). When the
difference between the switches is more than 2,5 seconds the system will be turned off.
Holding button (A) down for 2,5 seconds the colours slowly start to change and the signal lamp (K) on the control panel starts