Page 2
USING A DYNAMOMETER (ODU) is attached to the windshield pillar on the same side are conducted on a vehicle equipped with a Bendix ® as the radar sensor. The ODU warns the driver when one of Wingman system.
Page 3
10 foot by 24 foot for bus or straight frame sensor. Use the lower two mounting holes as a guide. See truck applications. See Figure 3. Figure 4. NOTE: Bendix does not certify, nor offer warranty on, Bendix BlindSpotter systems where system performance ™...
Page 4
Mirror 14" (355.6mm) Front of Radar Sensor Minimum Distance 5/16 from 22" Steps and Fuel Tank 48" 18" (558.8mm) (1219.2mm) (457.2mm) Figure 7 – Minimum Installation Clearance adar Sensor Figure 5 – Recommended Location for One R OPERATOR DISPLAY UNIT INSTALLATION See Figure 1.
Page 5
All wire harness connectors must be properly seated to maintain environmental seals. Push the mating connector until it clicks for a latched seal. Refer to the following steps to install the radar sensor harness. See Figure 10. 1. Insert the harness assembly six-pin connector into the radar sensor.
Page 6
DISPLAY Operator Display Unit. POWER-UP SYSTEM TEST The ODU indicators display system status at power-up. Refer to the Bendix BlindSpotter Side Object Detection Connector Front System Service Data Sheet SD-61-4933 for system indicators and alert notices during vehicle use. Typical System Indication/Alerts...
Page 7
Enforcement Bureau; 445 12th Street S.W.; Room 7-C485; Washington, DC 20054. Radar Sensor Substitution Install only radar sensors with recommended service replacements, as provided by Bendix. Contact the Bendix Tech Team at 1-800-AIR-BRAKE (1-800-247-2725), option 2, to request part number assistance.
Need help?
Do you have a question about the BlindSpotter and is the answer not in the manual?
Questions and answers