28. If the output assignments are not as shown, tap the Clear All Assignments button (split arrows); tap YES to the
warning dialog box; then tap the numeric buttons correctly route the audio to the appropriate physical output/s.
29. Tap the return key to close this screen and return to I/O CONFIG.
30. The following settings on the left-side of the I/O CONFIG screen should be correct by default; if they are
incorrect, please refer to the LAKE Controller Operation Manual for further details.
• PRIMARY DIGITAL CLOCK:
Internal – 96 kHz
• SRC CLOCK:
Internal – 88.2 kHz
• INPUT CONFIGURATION:
#1: Auto
Type: Analog
#2: Auto
Type: Analog
• DANTE CONFIGURATION:
Dante Disabled
• ANALOG ISO-FLOAT & AES TERMINATION:
Inputs 1-2:
Floating Outputs 1-6:
31. Tap the INPUT GAIN block on the interactive block diagram for Module A. The LEVELS screen displaying the
gain parameters for Module A will be displayed. This screen can also be accessed by returning to HOME and
tapping the Module icon.
Figure 6.1: Classic 3+1 Analog Output Configuration
Offset/Headroom: 26 dBu
Offset/Headroom: 26 dBu
Floating AES: Terminated