Bosch AdvancedLevel 360 Original Instructions Manual page 19

Hide thumbs Also See for AdvancedLevel 360:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
Cross line laser
Dimensions (length × width × height)
A) The working range may be reduced by unfavourable environmental conditions (e.g. direct sun-
light).
B) At 20–25 °C
C) Applies to the two intersection points and the corresponding opposite sides
D) The values stated presuppose normal to favourable environmental conditions (e.g. no vibration,
no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations
in accuracy.
E) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by
condensation is expected.
The serial number (13) on the type plate is used to clearly identify your measuring tool.
Assembly
Inserting/changing the batteries
It is recommended that you use alkaline manganese batteries to operate the measuring
tool.
To open the battery compartment cover (11), press on the locking mechanism (10) and
remove the battery compartment cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is correct according to the illustra-
tion on the inside of the battery compartment.
If the batteries are drained, the status display (3) will light up red and the laser beams
will be switched off. Switch off the measuring tool and replace the batteries.
Always replace all the batteries at the same time. Only use batteries from the same man-
ufacturer and which have the same capacity.
Take the batteries out of the measuring tool when you are not using it for a pro-
u
longed period of time. The batteries can corrode and self-discharge during pro-
longed storage in the measuring tool.
Operation
Starting Operation
Protect the measuring tool from moisture and direct sunlight.
u
Do not expose the measuring tool to any extreme temperatures or variations in
u
temperature. For example, do not leave it in a car for extended periods of time. In
case of large variations in temperature, allow the measuring tool to adjust to the ambi-
Bosch Power Tools
English | 19
AdvancedLevel 360
117 × 80 × 126 mm
1 609 92A 541 | (11.11.2019)