The butt connectors have a heat activated
waterproofing. When the butt connections
have been crimped, slowly apply heat with a
heat gun until you see sealant coming out of
the connector ends. It is recommended to
wrap the connections together with electrical
tape
for
further
connector into the rear of the depth sounder.
2)
If the transducer cable is not connected
properly or not plugged into the depth
sounder, or the boat is not in the water, the
display will blink when the power is applied
to the unit.
General description:
The depth sounder will display depth of
3-199 ft, 1-92 m, or 1-54 F. To allow greater
depths to be displayed in the "ft" (Feet)
mode the depth sounder will automatically
change to "F" (Fathoms) mode and continue
to display depths to approximately 54
fathoms.
When the depth decreases below 200 feet
the display will return to the "ft" mode.
Extreme depths may be limited by type of
transducers utilized or bottom conditions. If
the reading is less than 19.9 feet, meters or
fathoms,
1/10th
displayed.
If the reading is more than 19.9 feet, all
readings will be in whole numbers.
The depth sounder has an audible and LCD
displayed depth alarm with adjustable
shallow and deep limits and a depth below
keel offset feature. These settings once
made are stored in memory and will remain
even if the battery is disconnected.
Operation:
Power on
The
depth
sounder
automatically when the power to it is initially
turned on. You do not have to press the
combination "ON / OFF MODE" keypad.
The LCD will illuminate showing the depth
and will also show the type of units selected,
feet (FT), meters (M), or fathoms (F).
The LCD will illuminate showing the depth
in the upper display. The lower display will
show a "W" and the selected water
protection.
Plug
increments
will
will
activate
temperature.
Press the "Up" button and the lower
display will change to an "A" and the
ambient air temperature will be displayed.
Press the "Down" button to return to the
water temperature display.
the
To turn the depth sounder off, press and
hold the "ON / OFF MODE" keypad for 4
seconds. Pressing the "ON / OFF MODE"
keypad again will reactivate the unit.
Note:
The instrument is designed to have the
internal LED lighting remain on as long as
power is supplied even if the unit is turned
"off" at the keypad.
Depth alarm
Shallow mode:
Pressing the "ON / OFF MODE" keypad
again displays the "SH" shallow depth alarm
setting. This is the shallowest water that will
activate the alarm. Press and hold the up or
down arrow keypads to adjust the reading to
the desired depth.
Deep mode:
be
Pressing the "ON / OFF MODE" keypad
again displays the "DP" deep depth alarm
setting. This is the deepest water that will
activate the alarm. Press and hold the "Up"
or 'Down" arrow keypads to adjust the
reading to the desired depth.
When the shallow depth setting is read by
the depth sounder, the "SH" will flash on the
LCD and the audible alarm will sound
rapidly. When the deep depth setting is read
by the depth sounder, the "DP" will flash on
the LCD and the audible alarm will sound at
2 beeps per second.
Note:
To fully deactivate an alarm, reset it to zero.
Pressing the "ON / OFF MODE" keypad
temporarily
reactivate the alarm press the "ON / OFF
MODE" keypad until the depth reading
appears.
Keel offset
Pressing the "ON / OFF MODE" keypad
deactivates
the
alarm. To