Trouble
Push remote button and
nothing happens.
Push remote button and
lift bounces while raising lift.
Remote will not work from
a distance.
Hydraulic fluid tank seems low.
Push button on remotes,
pump runs, but will not move
lift either up or down.
Hydraulic pump squeals and will
not raise the boat completely.
(Cyclinder is not fully extended)
When running the pump, the
lift only goes down.
When running the pump, the
lift only goes up.
Page 16
12v 110v
DC
AC
Remedy
X
Check system shut-off switch. If switch is turned off,
the system will not operate.
X
12 volt battery low. Charge battery with battery charger.
X
Check battery cable connections.
X
X If remote fob blue light does not flash - replace batteries
X
Reprogram remote fobs - 12 Volt (DC)
X Reprogram remote fobs - 110 Volt (AC)
X
Use toggle switch inside box to raise lift. If toggle
switch works properly, but remote causes the lift
to bounce, the 12 volt battery is low. Charge battery.
X
Battery low. Charge battery with battery charger.
X
X Signal between remote and antenna may be weak.
Move closer to hydraulic box.
X
X When boat lift is completely lowered, there should be
1" to 1-1/2" of fluid in the tank. If there is less,
additional fluid can be added to reach the reccomended
level in the tank.
X
X Hose couplers not completely tighten. Use adjustable
wrench to tighten couplers.
X
X Pressure relief valve can be adjusted up.
Factory Setting : 2700 psi
Turning up pressure relief too high can cause damage
to the pump. Make only 1/4 turn and test.
X Valve / Coil without Bypass is not shifting.
X
X
X Hose couplers not completely tighten. Use adjustable
wrench to tighten couplers.
X
X Pull up Bypass for 1 second intervals. (2 to 3 Times)
This will remove any built up pressure in the line and may
dislodge small debris.
X
X Check for loose wires.
X
X Check if coil is grabing magnetically. If not, replace coil.
X
X Valve plugged : Remove valve, clean and replace
X
X Bypass Valve / Coil is not shifting
X
X Hose couplers not completely tighten. Use adjustable
wrench to tighten couplers.
X
X Pull up Bypass for 1 second intervals. (2 to 3 Times)
This will remove any built up pressure in the line and may
dislodge small debris.
X
X Check for loose wires.
X
X Check if coil is grabing magnetically. If not, replace coil.
X
X Valve plugged : Remove valve, clean and replace