Servpro HVE3000 Owner's Manual

Flood pumper and inline booster

Advertisement

HVE3000 Flood Pumper and Inline Booster
The high-efficiency HVE3000 can be used both as a flood pumper to quickly remove excess
liquid water for flood remediation and as an inline truckmount booster to extend the
effective vacuum hose length for carpet extraction and cleaning.
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
SAFETY INSTRUCTIONS
WARNING
WARNING! Do not alter or modify your HVE3000 in
any way. Use only replacement parts authorized by
Sapphire Scientific, Inc. Modifications or use of
unapproved parts could create a hazard and will
void your warranty. Contact your authorized
Sapphire distributor for assistance.
WARNING! Do not operate unit in standing water.
Electric shock hazard. Unit must be grounded.
WARNING! Unit must be grounded.
• Keep motor and wiring dry. Keep out of standing
water and do not install in area likely to be subject to
water intrusion. Do not expose to rain, water or
snow.
• Insert three-prong plug on power cord into a
matching electrically grounded outlet. Do not use
adapter. Never cut off third prong.
• Do not use an extension cord.
• To reduce the risk of fire or electric shock, do not
use this unit with any solid-state speed control
device.
FIRE HAZARD
• Keep away from open flames and heat sources.
• Do not use or store where vapors from gasoline,
solvents, thinners or other flammable materials may
be present.
SP004 HVE3000
Owner's Manual
Manufactured by Sapphire Scientific for Servpro Industries, Inc.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: 360-757-7950 www.SapphireScientific.com
Patents:
http://www.LBpatents.com
#633 - 115V
WARNING! Unplug unit before cleaning or servicing.
• Turn off unit and unplug before lifting or moving.
• Handle the unit carefully. Always operate the unit on
a stable, level surface. Do not drop, throw, or place
where it could fall. Rough treatment can damage the
unit, and may create a hazardous condition or void
the warranty.
• Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
• The unit must be operated on a 115V/60 Hz circuit
protected by a Ground Fault Circuit Interrupter
(GFCI) device.
• Do not attempt to repair the unit. For authorized
service options, contact SERVPRO
Department at 866-885-6833 or email
rma@servpronet.com.
BEFORE YOU BEGIN
Warranty registration
To process a warranty or repair claim, just click the
"RMA/ Warranty Form" listed under the "Products" tab
on the ServproNET
Equipment page on ServproNET.
You may contact the SERVPRO
phone at 866-885-6833 or via email at
rma@servpronet.com.
To expedite the warranty claim process, please have the
following:
Equipment model number.
Serial number.
Usage hours (if applicable).
When Franchises purchase equipment from Servpro
Industries, Inc. unit date of purchase and serial numbers
are recorded on the invoice. As part of the Servpro
Industries, Inc. RMA/Warranty program, proof of
purchase and equipment warranty records are added to
1
®
RMA
®
home page or it is also found at the
®
RMA Department by
Dri-Eaz Products, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HVE3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Servpro HVE3000

  • Page 1 15180 Josh Wilson Road, Burlington, WA 98233 Phone: 800-932-3030 Fax: 360-757-7950 www.SapphireScientific.com The high-efficiency HVE3000 can be used both as a flood pumper to quickly remove excess liquid water for flood remediation and as an inline truckmount booster to extend the effective vacuum hose length for carpet extraction and cleaning.
  • Page 2: Table Of Contents

    If the unit is covered under warranty, the RMA The HVE3000 can also be used as an inline booster Coordinator will communicate the repair and return and prefilter with a truckmount extractor to provide process.
  • Page 3: Parts Identification

    No light appears if a) the two cords are connected to the same circuit or b) if only one cord is connected. When using both power cords, do not operate the unit unless the green light is illuminated. SP004 HVE3000 Dri-Eaz Products, Inc.
  • Page 4: Extraction Mode Setup

    Recovery tank interior. EXTRACTION OPERATION TIP NOTE: Pump, float and Place the HVE3000 as close as possible to the end of float arm assembly are the hose run nearest the wand or other extraction tool. located inside tank.
  • Page 5: Maintenance

    Ask for Dri-Eaz part no. F503 TRUCKMOUNT BOOSTER OPERATION TIP or Sapphire part no. 20-045. Place the HVE3000 as close as possible to the end of Check the sump pump float valve (Fig. D). Remove the hose run nearest the wand or other extraction tool.
  • Page 6 If necessary, wipe out the tank with a towel. Loosen cord clamp on inside wall of tank with the 15/16 in. wrench, and pull in approximately two feet of cord or until the cord shows resistance. SP004 HVE3000 Dri-Eaz Products, Inc.
  • Page 7 Rinse all components clean and ensure float ball moves freely inside housing. Reinstall float ball housing. Loosen upper pump outlet hose clamp with the short- handled screwdriver and pull the hose off the outlet. SP004 HVE3000 Dri-Eaz Products, Inc.
  • Page 8 Fold up the pump handle and lift out the pump for inspection. Rest the pump on a table or other stable surface placed next to the unit. There is no need to disconnect the wire harness. SP004 HVE3000 Dri-Eaz Products, Inc.
  • Page 9 See Fig. B. Replace when the filter is visibly dirty. To access the filter, remove the filter cover plate thumbscrews and lift off the plate. Replacement filters are sold in packs of four. Ask for Dri-Eaz part no. F503 or Sapphire part no. 20-045. SP004 HVE3000 Dri-Eaz Products, Inc.
  • Page 10: Specifications

    SPECIFICATIONS FOR PARTS AND SERVICE CONTACT SERVPRO Model HVE3000 High Volume Extractor RMA DEPARTMENT. Weight 132 lbs. | 60 kg Dimensions 40.2 × 22.5 × 24.8 23.6 in. (H × W × D) 102.1 × 57.2 × 59.9 cm 12A (Blower 1 + Pumpout);...