Advertisement

Quick Links

INFORMATION
OPERATING
INSTRUCTIONS
CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ
ALL SECTIONS OF THIS INSTRUCTION MANUAL
IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY
1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
2. Connect the machine to a properly grounded outlet.
3. Keep machine from rain, snow, and extremes in temperatures. Store the machine in a
heated location. Use the machine indoors. Do not use outdoors.
4. Use approved chemicals only. NO SOLVENTS.
5. Wear gloves or use rags when removing quick disconnects to prevent burns.
6. Never use water above 130° F/54° C in the solution tank.
7. Never turn on the solution pump without your solution line connected to both the
machine and the tool.
MODEL 879
EXTRACTOR
120V
&
1
3/10 revised 11/11 Form No. 56041937

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 879 and is the answer not in the manual?

Questions and answers

Summary of Contents for Servpro 879

  • Page 1 MODEL 879 EXTRACTOR 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
  • Page 2: Important Safety Instructions

    • Use extra care when cleaning on stairs. • Connect to a properly grounded outlet only. • Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or chemical content. FORM NO. 56041937 - SERVPRO 879...
  • Page 3: Cleaning Solutions

    INSPECTION: Carefully unpack and inspect your 879 for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box, the machine, or its parts.
  • Page 4: Switch Plate

    Auto-fi ll Recovery Tank Hose Connection Vacuum Hose Power Cord Connection Pigtails Pressure Recovery Adjustment Cap Tank Drain Pump-out Hose Connection 12” Wheel Pressure Relief Valve Solution Castor (inside base Output compartment) FORM NO. 56041937 - SERVPRO 879 revised 11/11...
  • Page 5 Try other outlets with one of the cords until you get the locator light to come on. NOTE: if the heat switch is turned on when both cords are on the same circuit, the breaker in the wall may trip. FORM NO. 56041937 - SERVPRO 879...
  • Page 6 CAUTION: always use a defoamer in the recovery tank to prevent water or foam from entering the vacuum motor. CAUTION: Always make sure the fl oat cage is clean and the ball can travel freely before turning on the machine. FORM NO. 56041937 - SERVPRO 879...
  • Page 7 11/11 FORM NO. 56041937 - SERVPRO 879...
  • Page 8 Pump and motor, complete 1160K Pump rebuild kit, valves & O-rings 1160A Pump rebuild kit, plunger and seals * = Optional, Not Included [ ] = Not Shown = Revised or new since last update FORM NO. 56041937 - SERVPRO 879 revised 11/11...
  • Page 9: Maintenance Schedule

    No power to motor. Does the switch light up? If not, the switch may be bad or there may be no power getting to the switch. Check wiring connections. Test the switch with a volt/ohm meter. Test the vacuum motor by connecting it directly to AC. FORM NO. 56041937 - SERVPRO 879...
  • Page 10 MODEL #879 NOTES: SERVPRO INDUSTRIES, INC. 575 AIRPORT BLVD., GALLATIN, TN 37066 615-451-0200...