ECOMMENDED HYDRAULIC SUPPLY OPTIONS E-Series Clamps can be operated with any of the hydraulic supply arrangements shown below. Refer to Cascade Hose & Cable Reel Selection Guide , Part No. 212199, to select the correct hose reel for the mast and truck. The hose and fitting requirements are: •...
Page 3
(19 L/min.) (28 L/min.) (38 L/min.) Cascade E-Series Clamps are compatible with SAE 10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid is not recommended. If fire resistant hydraulic fluid is required, special seals must be used.
Page 4
Follow the steps shown to install the Clamp on the truck. Read and understand all WARNING and CAUTION statements. If you don't understand a procedure, ask your supervisor, or call the nearest Cascade Service Depart- ment for assistance. Attach overhead hoist...
Page 5
NSTALLATION Prepare Hoses IMPORTANT: Main valve options include LH or RH Determine hose lengths required for hydraulic CLAMP/OPEN porting, or dual porting which allows supply configuration of truck. hoses to be plumbed to either side of the Clamp to Cut hoses to length, install end fittings. match existing truck hydraulic supply configurations.
Page 6
NSTALLATION Mount Clamp on truck carriage Center truck behind Clamp. Tilt forward and raise carriage into position. Engage upper mounting hooks with car- riage. Make sure centering tab engages a notch on top carriage bar. NOTE: Center- ing tab can be oriented in 4 different positions to center Clamp (see illustration).
Page 7
NSTALLATION Connect hoses prepared in Step 3 to Attachment CL0247.ill CL0104.ill Internal Hose Reeving Hydraulic Supply Double Hose Reels Hydraulic Supply Install solenoid control knob – (Solenoid-equipped units) PRESS BUTTON SIDESHIFT TO POSITION Button toward driver Adapter Truck control valve handle CL0240.ill Install wiring –...
Page 8
NSTALLATION Cycle Clamp functions WARNING: Make sure all personnel are • With no load, cycle each Clamp function clear of the Clamp during testing. several times. • Check for operation in accordance with ITA (ISO) standards. • Clamp and lift a maximum load. Sideshift left and right.
Page 9
NSTALLATION Adjust relief cartridges WARNING: Before removing hydraulic lines or components, relieve pressure in the For over-pressure protection, the relief valve hydraulic system. Turn the truck off and cartridges for both the CLAMP and SIDE- open the truck auxiliary control valves SHIFT functions should be adjusted to several times in both directions.
Page 10
ERIODIC MAINTENANCE WARNING: After completing any service procedure, always test the Clamp through five complete cycles. First test the Clamp empty, then test with a load to make sure the Clamp operates correctly before returning it to the job. Cylinder Rod IMPORTANT: Attachment is prelubed at the Factory.
Page 11
Do you have questions you need answered right now? Call your nearest Cascade Service Department. Visit us online at www.cascorp.com AMERICAS Cascade Corporation Cascade Canada Inc. Cascade do Brasil U.S. Headquarters 5570 Timberlea Blvd. Rua João Guerra, 134 2201 NE 201st...