1-2. Operating cautions

• Do not open the cover of this device or put your hand
inside. Otherwise the internal circuit may be broken by
static electricity.
• This device is not explosion-proof. Do not use it in the
atmosphere of flammable gas.
• This device is not vibration resistant. Do not use it in a
place where it is subject to shocks. (Excluding the head
assembly)

1-3. Installation

• Use the PL25/PL60 in the temperature range of 0 to
45°C / 32 to 113°F. Do not expose it to the sunlight or
source of heat. A well-ventilated place is preferable.
• Install the PL25/PL60 at least 0.5 m away from noise
sources such as large-power relays, high-voltage
sources, large-current switch, Inverter high electric
power.
• Separately route the head cable and output cable from
the power line.
• When the system is exposed to cutting chips, oil and
coolant, provide a cover. Some coolants may affect the
functions of product.
protections.
10
Please provide necessary

2. Introduction

The PL25/PL60 is a DIGIRULER
cable, which, together with the SL110/SL130/SL331 scale
unit and MJ100/MJ110 detector, forms a position/
displacement measuring system.
System configuration
MJ100
PL25
SL110/SL130
Features
• The non-contact read head and scale unit is highly
resistant to vibrations, shocks and other harsh workshop
conditions.
• The head-scale clearance allows for a great tolerance,
making for easy installation.
• Shorter delay time in signal processing as compared with
the preceding models.
• Resolution PL25:10µm / PL60:5µm
read head unit with
®
Detector
MJ110
Head unit
PL60
Scale unit
SL331