Table 7. Subcooling
Values
For Fixed Orifice Systems
(HFC-410A)*
XC13 Outdoor
Condensing Units Models
°F (°C)**
-018
-024
-030
-036
-037
-042
-048
-060
65 (18)
8 (4.4)
14 (7.7)
10 (5.6)
10 (5.6)
--
13 (7.2)
15 (8.3)
11 (6)
70 (21)
4 (2.2)
13 (7.2)
9 (5)
8 (4.4)
--
12 (6.7)
14 (7.7)
10 (5.6)
75 (24)
3 (1.7)
12 (6.7)
8 (4.4)
7 (4)
--
11 (6)
13 (7.2)
10 (5.6)
80 (27)
2 (1)
11 (6)
7 (4)
7 (4)
--
11 (6)
12 (6.7)
10 (5.6)
85 (29)
2 (1)
11 (6)
6 (3.3)
6 (3.3)
--
10 (5.6)
11 (6)
9 (5)
90 (32)
2 (1)
9 (5)
5 (2.7)
5 (2.7)
--
9 (5)
10 (5.6)
9 (5)
95 (35)
2 (1)
9 (5)
4 (2.2)
4 (2.2)
--
8 (4.4)
9 (5)
8 (4.4)
100 (38)
1 (0.5)
7 (4)
4 (2.2)
4 (2.2)
--
7 (4)
9 (5)
8 (4.4)
105 (41)
1 (0.5)
6 (3.3)
3 (1.7)
3 (1.7)
--
7 (4)
8 (4.4)
7 (4)
110 (43)
1 (0.5)
6 (3.3)
2 (1)
2 (1)
--
6 (3.3)
7 (4)
7 (4)
115 (45)
1 (0.5)
5 (2.7)
2 (1)
2 (1)
--
5 (2.7)
6 (3.3)
6 (3.3)
XP13 Outdoor
Heat Pump Units Models
°F (°C)**
-018
-024
-030
-036
-037
-042
-048
-060
65 (18)
--
7 (4)
13 (7.2)
15 (8.3)
8 (4.4)
13 (7.2)
10 (5.6)
10 (5.6)
75 (24)
--
5 (2.7)
10 (5.6)
13 (7.2)
7 (4)
10 (5.6)
9 (5)
9 (5)
85 (29)
--
5 (2.7)
8 (4.4)
11 (6)
6 (3.3)
8 (4.4)
8 (4.4)
8 (4.4)
95 (35)
--
4 (2.2)
7 (4)
9 (5)
6 (3.3)
7 (4)
8 (4.4)
6 (3.3)
105 (41)
--
3 (1.7)
6 (3.3)
7 (4)
5 (2.7)
6 (3.3)
7 (4)
5 (2.7)
115 (45)
--
2 (1)
3 (1.7)
5 (2.7)
4 (2.2)
3 (1.7)
5 (2.7)
4 (2.2)
*
Liquid Subcooling
[ + 1<_F (.6<_C)]
** Outdoor
Ambient
Temperature.
CHARGE
USING
SUPERHEAT
METHOD
--(Fixed
Orifice Systems)
- Outdoor
Temp. >40°F (4°C)
This charging procedure should not be used if ambient temperatures
are below 40°F (4°C), For best results, indoor
temperature should be 70°F (21°C) to 80°F (26°C), Measure the wet bulb temperature of indoor return air and dry bulb
temperature of the outdoor entering air, Use table 8 to find the superheat
value at those conditions,
Table 8. Superheat
Values
For Fixed Orifice
Systems
*D_ bulb
Wet bulb (air entering
indoor
coil)
ou_oor
50
52
54
56
58
60
62
64
66
68
70
72
74
76
40
15
18
20
23
26
29
32
34
38
41
43
46
48
51
45
13
16
18
21
24
27
30
33
36
39
41
44
46
49
50
11
14
16
19
22
25
28
31
34
37
39
42
44
47
55
9
12
14
17
20
23
27
30
33
36
38
40
42
44
60
7
10
12
15
18
21
24
27
30
33
35
38
40
43
65
6
10
13
16
19
21
24
27
30
33
36
38
41
70
7
10
13
16
19
21
24
27
30
33
36
39
75
6
9
12
15
18
21
24
28
31
34
37
80
5
8
12
15
18
21
25
28
31
35
85
8
11
15
19
22
26
30
33
90
5
9
13
16
20
24
27
31
95
6
10
14
18
22
25
29
100
8
12
16
21
24
28
105
5
9
13
17
22
26
110
6
11
15
20
25
115
8
14
18
24
* Dry-bulbtemperature (°F)of outdoor entering air.
NOTE- Do not attempt to charge system where a dash appears, system could be overcharged. Superheat is taken at vapor line service port. Vapor
line superheat mum never be lessthan 5°F at the vapor line service port,
505059M