12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker. 13. Do not lift the pump by the power cord. 14. Know the pump and its applications, limitations, and potential hazards. 15.
NOTICE: Do not reduce size of discharge pipe or hose below 1-1/2” diameter. If discharge is too small, pump will overheat and fail prematurely. NOTICE: If a Carbon Monoxide (CO) sensor is installed, it must be at least 15 feet away from battery charger in order to avoid nuisance CO alarms.
PACKAGE CONTENTS Part Description Pump Battery box adaptor Do not reduce size of discharge pipe or hose below 1-1/2 in. diameter. If discharge is too small, pump NOTE: will overheat and fail prematurely. This pump is designed for use in a residential sump only. Only pump water with this pump.
Page 6
NOTICE: Remove all sand, clay, and gravel before installing. 5. Install the outlet pipe on the quick connector. NOTICE: The quick connector must be tightened. 6. Place Combo Kit into sump pit. Make sure vertical float switches can operate freely inside sump pit, once the Combo Kit is firmly seated in the base of the pit, then connect the pump outlet pipe to the top outlet pipe with a hose clamp assembly.
Page 7
8. Place the battery (sold separately) into the control box. Connect the leads from controller: Red+ to battery Red+; Black- to battery Black-. Note: Be sure the battery box ventilation holes are unobstructed. Battery control box must be set up in a well-ventilated area. Smoking and open flames are prohibited. NOTICE: If the leads are reversed, the pump will run backward and not pump water.
10. Battery backup system testing To verify the system is operational, press “RESET” button 1–4 seconds. The system will complete a self-testing diagnostic. The DC pump will run for 3 seconds. Green light is on: The system is normal. Yellow light quickly flashes and alarm sounds: Battery disconnected or DC fuse blown. Connect the battery or replace the fuse.
cords, clogged impeller, very low head or lift, or a plugged or frozen discharge pipe, etc., could cause cycling. 3. Pump will not remove all water. If operating a pump manually and suddenly no water comes out of the discharge hose, shut off the unit immediately. The unit has broken prime due to a very low water level. Risk of electric shock.
Page 10
PRIMARY PUMP TROUBLESHOOTING Symptom Possible Cause(s) Corrective Action Pump won’t start or run No power. Reset GFCI switch/Reset the breaker/Secure the plug/Clean the plug prongs. The impeller is blocked. Remove the debris around the impeller. The float switch failed. Replace the float switch. The motor failed.
Page 11
REPAIR PARTS-PRIMARY PUMP Description shaft impeller Gasket Bottom plate screws REPAIR PARTS-BATTERY BACKUP UNIT Description quick connector Combo Plumbing Primary Pump check valve Backup pump check valve DC Backup pump Gasket impeller volute Battery box adaptor For Professional Technical Support call 1-844-242-2475...
WARRANTY Limited Warranty WHAT THIS WARRANTY COVERS When used and maintained in normal use and in accordance with the Owner’s Manual, your K2 product is warranted against original defects in material and workmanship for at least one year (warranty varies depending on model; see box for specific warranty information) from the date of purchase (the “Warranty Period”).