Download Print this page

Cres Cor AquaTemp CO-151-FWUA-12DX2081BC Installation, Operation And Maintenance Manual

Humidity convection ovens

Advertisement

Quick Links

Convection
FL-2373-BC
Humidity Oven
Page 1 of 17
Rev. 1 (8/20)
5925 Heisley Road • Mentor, OH 44060-1833
INSTALLATION, OPERATION and MAINTENANCE MANUAL
for Cres Cor AquaTemp
HUMIDITY CONVECTION OVENS
BUC-EE'S PROGRAMMING REVISION J-05
CO-151-FWUA-12DX2081BC
CO-151-XWUA-5DXM2081BC
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaTemp CO-151-FWUA-12DX2081BC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cres Cor AquaTemp CO-151-FWUA-12DX2081BC

  • Page 1 Page 1 of 17 Rev. 1 (8/20) 5925 Heisley Road • Mentor, OH 44060-1833 INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor AquaTemp HUMIDITY CONVECTION OVENS ™ BUC-EE’S PROGRAMMING REVISION J-05 CO-151-FWUA-12DX2081BC CO-151-XWUA-5DXM2081BC Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 2 DO NOT OPEN WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 3 (see “How to use Automatic fill kit on page 7) . CAUTION Use of treated water is recommended for proper operation and to maintain warranty. It will reduce scaling. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 4 CRES COR : ROAST AND HOLD UNDERCOUNTER OVEN Buc-ee’s Quick Start Guide Cres Cor : Roast and Hold Undercounter Oven BUC-EE’S QUICK START GUIDE Turn power switch on: 1. Turn power switch on: Turn power switch on: Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 5 5925 Heisley Road • Mentor, OH 44060-1833 Wait for preheat. 2. Wait for preheat. Insert meat probe. 3. Insert meat probe. Then, load product. Insert meat probe. Load product. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com Load product.
  • Page 6 Press CANCEL to start over. Press CANCEL to start over. Press CANCEL to start over. Press START to begin preheating a new cycle. Press START to begin preheating a new cycle. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 7 . Hold temp setpoint b . “t” hold time NOTE: The cook cycle will keep the oven at cook temp setpoint until probe temp setpoint has been reached . Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 8 This trial unit uses prototype software. If the controls freeze up or something is happening that shouldn’t, please turn the power switch OFF. Do not re-start oven for at least 30 seconds. Any fault should be cleared. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 9 Auto Fill option: 1 . Scroll over to “FILL” and press “push to set” button to edit . 2 . Select “Y” or “N” . 3 . Scroll to end . Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 10 AUTO FILL: If water level is low and water supply is not connected, an error code will display after a time limit . (See MENU SETTINGS to turn auto fill on and off) Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 11 Stainless Steel. directions. (Stainless Steel) HARD WATER SPOTS & 1. Swab or wipe with cloth. Vinegar SCALE 2. Rinse and dry. * Mild detergents include soaps and non-abrasive cleaners Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 12 4 . Fuse on back of unit is blown . NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement of electrical components must be done by a qualified electrician. Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 13 - recipe number ## err 0 (roast and hold controller) – sensor out of range err 0 (aquatemp controller) – sensor out of range err 1 (aquatemp controller) – autofill timeout Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 14 0569-306-K 0569-306-K 0569-310 Casters w/Brake 0569-306-BK 0569-306-BK 0569-306-BK 0569-306-BK 0569-310-B Posts 0696-250 0696-250 0696-250 0696-250 0696-252 Air Tunnel 0546-146-C 0546-146-C 0546-146-C 0546-161 0546-162 Pan, Drip 1017-058 1017-058 1017-058 1017-058 1017-098 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 15 4700W, 1PH 4700W, 3PH Power Cord 0810-124 0810-132 0810-163 0810-164 Heater Kit, 208V 0811-306 0811-306 0811-311 0811-311 Heater Kit, 240V 0811-305 0811-305 0811-312 0811-312 Strain Relief 0818-061 0818-050 0818-102 0818-050 Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 16 Convection FL-2373-BC Humidity Oven Page 16 of 17 Rev. 1 (8/20) 5925 Heisley Road • Mentor, OH 44060-1833 WIRING DIAGRAM OVENS CO151FW SERIES 208/240V 1 Ph Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...
  • Page 17 Convection FL-2373-BC Humidity Oven Page 17 of 17 Rev. 1 (8/20) 5925 Heisley Road • Mentor, OH 44060-1833 WIRING DIAGRAM OVENS CO151FW SERIES 208/240V 3 Ph Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com...

This manual is also suitable for:

Aquatemp co-151-xwua-5dxm2081bc