SPEEDMASTER™ OPERATION MANUAL

Field Output

The field output is for shunt wound motors only. Do not make
any connections to F1 and F2 when using a permanent magnet
motor. Use 18 AWG wire to connect the field output to a shunt
wound motor. Table 2 lists the field output connections.
Line Voltage
(VAC)
115
115
230
230

Voltage Switches

• Set voltage switch SW501 to either 115 or 230 to match the
AC line voltage (see Figure 4 below).
• Set voltage switch SW502 to either 90 or 180 to match the
maximum armature voltage (see Figure 4 below).
MAX ARMATURE VOLTAGE SWITCH
SW502 (90 or 180 VDC)
AC LINE VOLTAGE SWITCH
SW501 (115 or 230 VAC)

Table 2. Field Output Connections

Approx. Field
Voltage (VDC)
50
100
100
200
T501

Figure 4. Voltage Switches

C501
IC502
TQ LIMIT
SW501
R501
IR COMP
230 - 115
Installation
Connect Motor
Field To
F1 and L1
F1 and F2
F1 and L1
F1 and F2
ACCEL
DECEL
MIN SPD
MAX SPD
9