Johnson & Starley Reno HE30C Fitting Instructions

Advertisement

Quick Links

Johnson & Starley
HE30C Timer Fitting Instructions
Contents
Item
Timer/Programmer
Fixing Screws
Instructions
1. Isolate the boiler from the electrical supply at the fused
spur
NB (the on off switch on the front of the control panel will
not isolate the timer connections.)
2. Remove the lower flip door by opening and unclipping it
from the hinges.
3. Take off the front panel from the boiler by removing the
fixing screw located at the top and lifting the panel
upwards
4. Remove the two fixing screws that secure the electrical
module and hinge it down.
Fixing Screw
Push Panel Upwards
Quantity
1
4
1
Reno
Fixing Screws
5. Remove the two fixing screws from the left hand control
panel back plate, lift up the left hand end of the panel
and slide the location lugs out of the slots.
Fixing Screws
Publication: ZZ1197/1

Advertisement

loading

Summary of Contents for Johnson & Starley Reno HE30C

  • Page 1 Publication: ZZ1197/1 Reno Johnson & Starley HE30C Timer Fitting Instructions Contents Item Quantity Timer/Programmer Fixing Screws Instructions 1. Isolate the boiler from the electrical supply at the fused spur NB (the on off switch on the front of the control panel will not isolate the timer connections.) 2.
  • Page 2 6. Disconnect the blue, brown and the two orange wires 10. Refit the back plate on the rear of the control module from the parked position on the rear of the timer blank. and secure with the two screws previously removed. 11.