Configuration; Factory Settings; Configuration Options - TCS FBO1200-0400 Product Information

Interface for tk systems
Table of Contents

Advertisement

04/2013

Factory settings

Factory settings see FBO1200 brief overview of all commands.

Configuration options

co
mm
function
and
10
enter a PIN
11
determine the dialing register number for the sensor
12
enter or delete a call number in the dialing register
13
check the of the dialing register XX
not available  acknowledgement: invalid entry
14
15
set the minimum duration of a conversation
16
determine the number of calls until the TK-Interface accepts the call
17
set the activation time of the output port for
button 
not available  acknowledgement: invalid entry
18
19
service function listen-in
not available  acknowledgement: invalid entry
20
not available  acknowledgement: invalid entry
21
22
train an internal client to the buttons 4 / 5 / 6,
delete the buttons 4 / 5 / 6
23
control the remote maintenance
24
define the function of the sensor
25
define the type of the connection start.
26
set the delay of the dialing start
not available  acknowledgement: invalid entry
27
not available  acknowledgement: invalid entry
28
not available  acknowledgement: invalid entry
29
30
duration of the call for this dialing register
31
control of the connection establishment
32
control of the override tone during a call from a front-door station
33
enter the AS-address to the sensor in case of a voice connection
34
starts the transmission of the internal parameter block of the TK-
Interface
35
starts the read-out of the parameter block to the dialing register
36
enter the project number with 4 digits
37
control of the error output tone
38
set the function of an internal call to the TK-Interface
39
activate the function input PIN
40
set the timeout after the dialing
41
set the door release command
not available  acknowledgement: invalid entry
42
43
set the reaction on a call at the TK-Interface
44
blank dial tones / do not modify
acoustic note "call at the TK-Interface" when incoming call on / off
45
46
number of dialing register / set the type of the TK-Interface
not available  acknowledgement: invalid entry
47
not available  acknowledgement: invalid entry
48
49
max. permitted loop resistance between TK-Interface and power supply
and control unit
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129  Mail: hotline@tcsag.de
11

Configuration

Not in case of a call diversion!
* in Zusammenhang mit Konfiguration der Außenstation
configo
manually
as of version
1.8.x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Subject to technical changes.