Table 6: Altitude-Specific DIP Switch Settings (Indoor Models)
Indoor models: Propane
ELEVATION
LEVEL
0 to 2,000
0
(DEFAULT)
2,000 to
1
3,000
2*
3,000 to
5,000
3
4*
5,000 to
7,500
5
7,500 to
6
10,100
Special
Indoor models: Natural Gas
ELEVATION
LEVEL
0 to 2,000
0
(DEFAULT)
2,000 to
1
3,000
2*
3,000 to
5,000
3
4*
5,000 to
7,500
5
7,500 to
6
10,100
Special
*The se
are not listed in the Installa
See DIP switch graphics on page 19.
20 • Condensing Models: On-Demand Water Heater Service Handbook
DIPSWITCH SETTINGS
NO.3
NO.4
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
DIPSWITCH SETTINGS
NO.3
NO.4
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
manual and owner's
OUTPUT
REDUCTION
NO.5
OFF
N/A
OFF
N/A
OFF
-3 %
ON
-5 %
ON
-7 %
ON
-11 %
ON
%
OFF
N/A
OUTPUT
REDUCTION
NO.5
OFF
N/A
OFF
N/A
OFF
-4 %
ON
-6 %
ON
-8 %
ON
-11 %
ON
%
OFF
N/A
of 140 (T-H3M)
FAN MOTOR
SPEED CHANGE
N/A
3 %
5 %
7 %
9 %
11 %
%
-7%
FAN MOTOR
SPEED CHANGE
N/A
7%
10 %
15 %
17 %
20 %
%
-7 %

Hide quick links: